Event Reporting: Templates and Codes D–65
09C80101 Remote FLM detected an invalid facility to act upon.
Last Failure Parameter [0] contains the facility found.
09C90101 Remote FLM detected an invalid work type.
Last Failure Parameter [0] contains the work type found.
09CA0101 Remote FLM detected an invalid work type.
Last Failure Parameter [0] contains the work type found.
09CB0012 Remote FLM detected that the other controller has a facility lock manager at an
incompatible revision level with this controller.
Last Failure Parameter [0] contains the controller’s FLM revision.
Last Failure Parameter [1] contains the other controller’s FLM revision.
0A020100 ILF$CACHE_READY unable to allocate necessary DWDs.
0A030100 ILF$CACHE_READY buffers_obtained > non-zero stack entry count.
0A040100 ILF$CACHE_READY DWD overrun.
0A050100 ILF$CACHE_READY DWD underrun.
0A060100 ILF$CACHE_READY found buffer marked for other controller.
0A070100 CACHE$FIND_LOG_BUFFERS returned continuation handle > 0.
0A080100 Not processing a bugcheck.
0A090100 No active DWD.
0A0A0100 Current entry pointer is not properly aligned.
0A0B0100 Next entry pointer is not properly aligned.
0A0C0100 Next entry was partially loaded.
0A0E0100 Active DWD is not a DISK WRITE DWD as expected.
0A0F0100 New active DWD is not a DISK WRITE DWD as expected.
0A100100 Data buffer pointer is not properly aligned.
0A120100 Data buffer pointer is not properly aligned.
0A130100 Data buffer pointer is not properly aligned.
Table D–3 Last Failure Codes (Continued)