Event Reporting: Templates and Codes D–53
02FC0180 The FX detected a compare error for data that was identical. This error has always
previously occurred due to a hardware problem.
02FD0100 The controller has insufficient free memory to restore saved configuration information
from disk.
02FE0105 A field in the VSI was not cleared when an attempt was made to clear the interlock.
Last Failure Parameter [0] contains the NV index of the VSI on which the
problem was found.
Last Failure Parameter [1] contains the contents of the enable_change field of the
VSI, which should be zero.
Last Failure Parameter [2] contains the contents of the desired_state field of the
VSI, which should be zero.
Last Failure Parameter [3] contains the contents of the completion_routine field of
the VSI, which should be zero.
Last Failure Parameter [4] contains the contents of the open_requests field of the
VSI, which should be zero.
03010100 Failed request for port-specific scripts memory allocation.
03020101 Invalid SCSI direct-access device opcode in misc command DWD.
Last Failure Parameter [0] contains the SCSI command opcode.
03040101 Invalid SCSI CDROM device opcode in misc command DWD.
Last Failure Parameter [0] contains the SCSI command opcode.
03060101 Invalid SCSI device type in PUB.
Last Failure Parameter [0] contains the SCSI device type.
03070101 Invalid CDB Group Code detected during create of misc cmd DWD
Last Failure Parameter [0] contains the SCSI command opcode.
03080101 Invalid SCSI OPTICAL MEMORY device opcode in misc command DWD.
Last Failure Parameter [0] contains the SCSI command opcode.
03090101 Failed request for allocation of pci miscellaneous block Last Failure Parameter [0]
contains the failed dwd command class.
030A0100 Error DWD not found in port in_proc_q.
Table D–3 Last Failure Codes (Continued)
Code Description