Hp Array Controller HSG V8.7 Software Manuale Utente Pagina 161

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 160
Troubleshooting 47
Mirrored cache;
controller reports cache
or mirrored cache has
failed.
Primary data and its
mirrored copy data are
not identical.
SHOW
THIS_CONTROLLER
indicates that the cache
or mirrored cache has
failed.
Spontaneous FMU
message displays:
Primary cache
declared failed - data
inconsistent with
mirror, or Mirrored
cache declared failed -
data inconsistent with
primary.
Enter the SHUTDOWN
command on
controllers that report
the problem. (This
command flushes the
contents of cache to
synchronize its primary
and mirrored data.)
Restart the controllers
that you shut down.
Table 41 Troubleshooting Table (Continued)
Symptom Possible Cause Investigation Remedy
Vedere la pagina 160
1 2 ... 156 157 158 159 160 161 162 163 164 165 166 ... 575 576

Commenti su questo manuale

Nessun commento