B38 HSG80 Users Guide
Specify NODESTROY_UNFLUSHED_DATA in the following
situations:
If the controller module has been replaced
If the controllers nonvolatile memory (NVMEM) has lost its
contents.
Specify DESTROY_UNFLUSHED_DATA in the following situations:
If the cache module has been replaced
Any other reason not listed above
Caution Specifying the DESTROY_UNFLUSHED_DATA switch
destroys data remaining in cache, which can result in data loss.
Examples
This example shows how to clear an invalid cache error on this
controller after you have replaced a controller module. Enter the
command on one line.
CLEAR_ERRORS THIS_CONTROLLER INVALID_CACHE
NODESTROY_UNFLUSHED_DATA
This example shows how to clear an invalid cache error on the other
controller after a cache module has been replaced. Enter this command
on the same line. Enter the command on one line.
CLEAR_ERRORS OTHER_CONTROLLER INVALID_CACHE
DESTROY_UNFLUSHED_DATA
See also
CLEAR_ERRORS CLI
CLEAR_ERRORS LOST_DATA
CLEAR_ERRORS UNKNOWN
CLEAR_ERRORS UNWRITEABLE_DATA