Replacement Procedures 535
6. Enter option 3, Replace a PVA module from the FRUTIL Main menu.
FRUTIL displays the PVA Replacement menu:
FRUTIL PVA Replacement Menu:
1. Master Enclosure (ID 0)
2. First Expansion Enclosure (ID 2)
3. Second Expansion Enclosure (ID 3)
4. Exit
Enter Choice: 1, 2, 3, or 4 ->
Note The HSG80 controller can support up to three enclosures. The
FRUTIL PVA Replacement Menu has options for three enclosures
regardless of how many enclosures are connected.
7. Enter option 1, Master Enclosure (ID 0), from the FRUTIL PVA
Replacement Menu. FRUTIL displays the following:
Do you have a replacement PVA module? Y/N
8. Enter Y(es) and press return. FRUTIL displays the following:
Ensure the replacement PVAs address is set to zero.
Press return to quiesce device port activity.
9. Set the replacement PVAs address to zero.
10. Press return and wait for FRUTIL to quiesce the device ports. This may
take several minutes. FRUTIL displays the following:
All device ports quiesced.
Replace the PVA in the master cabinet.
11. Remove the old PVA and install the new PVA. FRUTIL displays the
following:
Press return to resume device port activity.
12. Press return to resume device port activity (this may take several
minutes). When all port activity has restarted, FRUTIL displays the
following:
PVA replacement complete.