Hp Array Controller HSG V8.7 Software Manuale Utente Pagina 190

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 189
4–36 HSG80 User’s Guide
Tachyon Status
The number that appears in the Tachyon Status field represents the
current state of the Tachyon, or Fibre Channel control chip. It consists
of a two-digit hex number, the first of which is explained in Figure
4–12. The second digit is outlined in Figure 4–13. Refer to the Tachyon
user’s manual for a more detailed explanation of the Tachyon
definitions.
Table 4–12 Tachyon First Digit
State Definition State Definition
0 MONITORING 8 INITIALIZING
1 ARBITRATING 9 O_I INIT FINISH
2 ARBITRATION WON A O_I PROTOCOL
3 OPEN B O_I LIP RECEIVED
4 OPENED C HOST CONTROL
5 XMITTED CL0SE D LOOP FAIL
6 RECEIVED CLOSE F OLD PORT
7 TRANSFER
Table 4–13 Tachyon Second Digit
State Definition State Definition
0OFFLINE 6LR2
1OL1 7LR3
2OL2 9LF1
3OL3 ALF2
5 LR1 F ACTI VE