Hp Array Controller HSG V8.7 Software Manuale Utente Pagina 476

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 475
D42 HSG80 Users Guide
01910084 A Cache Module was inserted or removed.
Last Failure Parameter [0] contains the value of actual Cache Module A exists
state.
Last Failure Parameter [1] contains the value of actual Cache Module B exists
state.
Last Failure Parameter [2] contains the value of expected Cache Module A exists
state.
Last Failure Parameter [3] contains the value of expected Cache Module B exists
state.
01920186 Unable to read the FX because a Device Port or a Host Port locked the PDAL bus.
Last Failure Parameter [0] contains the value of read diagnostic register 0.
Last Failure Parameter [1] contains the value of read diagnostic register 1.
Last Failure Parameter [2] contains the value of read diagnostic register 2.
Last Failure Parameter [3] contains the value of write diagnostic register 0.
Last Failure Parameter [4] contains the value of write diagnostic register 1.
Last Failure Parameter [5] contains the IBUS address of error register.
01932588 An error has occurred on the CDAL.
Last Failure Parameter [0] contains the value of read diagnostic register 0.
Last Failure Parameter [1] contains the value of read diagnostic register 1.
Last Failure Parameter [2] contains the value of write diagnostic register 0.
Last Failure Parameter [3] contains the value of write diagnostic register 1.
Last Failure Parameter [4] contains the IBUS address of error register.
Last Failure Parameter [5] contains the PCFX CDAL control / status register.
Last Failure Parameter [6] contains the previous CDAL address of error register.
Last Failure Parameter [7] contains the current CDAL address of error register.
01942088 An error has occurred on the PDAL.
Last Failure Parameter [0] contains the value of read diagnostic register 0.
Last Failure Parameter [1] contains the value of read diagnostic register 1.
Last Failure Parameter [2] contains the value of write diagnostic register 0.
Last Failure Parameter [3] contains the value of write diagnostic register 1.
Last Failure Parameter [4] contains the IBUS address of error register.
Last Failure Parameter [5] contains the PCFX PDAL control / status register.
Last Failure Parameter [6] contains the previous PDAL address of error register.
Last Failure Parameter [7] contains the current PDAL address of error register.
Table D3 Last Failure Codes (Continued)
Code Description
Vedere la pagina 475
1 2 ... 471 472 473 474 475 476 477 478 479 480 481 ... 575 576

Commenti su questo manuale

Nessun commento