Hp Array Controller HSG V8.7 Software Manuale Utente Pagina 381

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 380
CLI Commands B109
TERMINAL_SPEED=baud_rate
TERMINAL_SPEED=9600 (Default)
Sets the terminal transmission and reception speed (baud rate) to 4800,
9600 (default), or 19200 baud. When changed, the new value entered
for this switch takes effect immediately.
TIME=ddmmmyyyy:hh:mm:ss
Sets the date and time. The time is set on both controllers in a dual-
redundant configuration.When changed, the new value entered for this
switch takes effect immediately.
Examples
This example shows how to change the other controller's CLI prompt:
SET OTHER_CONTROLLER PROMPT=CONTROLLER B
See also
SHOW THIS_CONTROLLER
SHOW OTHER_CONTROLLER