D46 HSG80 Users Guide
027B0102 An invalid status was returned from VA$XFER() in a complex ACCESS operation.
Last Failure Parameter[0] contains the DD address.
Last Failure Parameter[1] contains the invalid status.
027D0100 Unable to allocate memory for a Failover Control Block.
027E0100 Unable to allocate memory for a Failover Control Block.
027F0100 Unable to allocate memory for a Failover Control Block.
02800100 Unable to allocate memory for a Failover Control Block.
02840100 Unable to allocate memory for the XNode Array.
02860100 Unable to allocate memory for the Fault Management Event Information Packet used
by the Cache Manager in generating error logs to the host.
02880100 Invalid FOC Message in cmfoc_snd_cmd.
028A0100 Invalid return status from DIAG$CACHE_MEMORY_TEST.
028B0100 Invalid return status from DIAG$CACHE_MEMORY_TEST.
028C0100 Invalid error status given to cache_fail.
028E0100 Invalid DCA state detected in init_crashover.
02910100 Invalid metadata combination detected in build_raid_node.
02920100 Unable to handle that many bad dirty pages (exceeded MAX_BAD_DIRTY). Cache
memory is bad.
02930100 There was no free or freeable buffer to convert bad metadata or to borrow a buffer
during failover of bad dirty.
02940100 A free Device Correlation Array entry could not be found during write-back cache
failover.
02950100 Invalid DCA state detected in start_crashover.
02960100 Invalid DCA state detected in start_failover.
02970100 Invalid DCA state detected in init_failover.
02990100 A free RAID Correlation Array entry could not be found during write-back cache
failover.
Table D3 Last Failure Codes (Continued)