Hp Array Controller HSG V8.7 Software Manuale Utente Pagina 259

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 258
Upgrading the Subsystem 613
4. Start HSUTIL with the following command:
RUN HSUTIL
HSUTIL displays the following:
HSUTIL Main Menu:
0. Exit
1. Disk Format
2. Disk Device Code Load
3. Tape Device Code Load
4. Disaster Tolerance Backend Controller Code Load
Enter function number: (0:4) [0]?
5. Enter option 2, Disk Device Code Load, from the HSUTIL menu.
6. Choose the single-disk unit as the source disk for the download.
7. Enter the starting LBN of the firmware imageusually LBN 0.
8. Enter the product ID of the device you want to upgrade. This ID
corresponds to the product information thats reported in the Type
column when you issue the SHOW DISK FULL command.
HSUTIL lists all devices that correspond to the product ID you entered.
9. Enter the disk or tape name of the device you want to upgrade.
10. Confirm or enter the byte count of the firmware image.
11. Confirm the download.
12. Some disk firmware releases require that you reformat the disk after
upgrading its firmware. See the documentation that accompanied the
firmware to determine if you need to reformat the device.
13. When HSUTIL finishes downloading the firmware, it displays the new
firmware revision for the disk drive.
Vedere la pagina 258
1 2 ... 254 255 256 257 258 259 260 261 262 263 264 ... 575 576

Commenti su questo manuale

Nessun commento