B112 HSG80 Users Guide
If you specify the NOTRANSPORTABLE switch and there is no
metadata on the unit, the unit must be initialized. If you specify
TRANSPORTABLE for a disk that was originally initialized as a
NOTRANSPORTABLE, you should initialize the disk.
Note DIGITAL recommends you avoid specifying
TRANSPORTABLE unless transportability of the device or media is
imperative and there is no other way to accomplish moving the data.
Examples
This example shows how to set the data transfer rate of DISK20000 to
5MHz:
SET DISK20000 TRANSFER_RATE_REQUESTED=5MHZ
This example shows how to set DISK10300 to transportable:
SET DISK10300 TRANSPORTABLE
See also
ADD DISK