Troubleshooting
3-4 HP Smart Array Multipath Software User Guide
HP CONFIDENTIAL
Writer: Rob Weaver File Name: d-ch3 Troubleshooting.doc
Codename: BorealisII Part Number: 307958-003 Last Saved On: 9/19/03 9:22 AM
Cable Failure
To replace the failed cable:
1. Power down the HBA in one of the following ways:
For a PCI-based HBA in a Microsoft operating system environment, use the
PCI Hot Plug functionality in the server to remove the HBA while the server
is online.
For an embedded HBA in a Microsoft operating system environment, power
down the server.
For an HBA in a Linux operating system environment, power down the
server.
2. Disconnect the SCSI cable:
a. Disconnect the cable from the MSA500 system.
b. Disconnect the cable from the connector on the HBA or from the external
VHDCI connector on the server.
3. Connect the replacement cable:
a. Connect the cable to the connector on the HBA or to the external VHDCI
connector on the server.
b. Connect the cable to the MSA500 system.
4. Apply power to the replacement HBA in one of the following ways:
Use PCI Hot Plug functionality to restore power (PCI-based Microsoft Only).
Power up the server.