Installation and Operation
2-2 HP Smart Array Multipath Software User Guide
HP CONFIDENTIAL
Writer: Rob Weaver File Name: c-ch2 Installation and Operation.doc
Codename: BorealisII Part Number: 307958-003 Last Saved On: 9/19/03 9:20 AM
4. Depending on the operating system, do one of the following:
If the server has a Microsoft operating system, be sure that only one SCSI
cable is connected from the server to the MSA500 system. During
installation, the Smart Array Multipath software supports only one SCSI path
per Microsoft-based server.
If the server has a Red Hat or SuSE Linux operating system, edit the active
kernel and modify the RAIDTAB configuration. Refer to “Additional
Red Hat and SuSE Linux Preparations” in Chapter 1.
5. Power up the storage system. Wait for the controller display to provide a “Startup
Complete” message.
6. Power up one of the servers.
Installing the Smart Array Multipath Software
Upgrade Procedures for Microsoft Operating Systems
Use the appropriate procedure in this section when upgrading the multipath software
or your Microsoft operating system.
IMPORTANT: Systems running Microsoft Windows 2000 with Service Pack 4 or Windows
Server 2003 must use Smart Array Multipath Software v2.0 or later.
Upgrading to Windows 2000 Service Pack 4 or Later
1. Uninstall Smart Array Multipath software v1.0, if installed. Refer to
“Uninstalling the Smart Array Multipath Software Driver” in this chapter.
2. Install the service pack.
3. Install Smart Array Multipath software v2.0 or later. Refer to “First-Time
Installation” in this chapter.
Upgrading to Microsoft Windows Server 2003
To upgrade your operating system to Microsoft Windows Server 2003: