Installation and Operation
2-4 HP Smart Array Multipath Software User Guide
HP CONFIDENTIAL
Writer: Rob Weaver File Name: c-ch2 Installation and Operation.doc
Codename: BorealisII Part Number: 307958-003 Last Saved On: 9/19/03 9:20 AM
8. Click OK.
NOTE: A Microsoft Windows Server 2003 system does not indicate progress during the
removal. Wait at least 10 minutes to allow the system to complete the removal.
9. Click Cancel.
10. Shut down the server.
11. Disconnect the SCSI cable from the redundant HBA.
First-Time Installation
1. To install the Smart Array Multipath software, refer to the HP Smart Array
Multipath Software CD Installation Instructions that ship with the CD.
2. After completing the installation instructions, depending on the operating system,
do one of the following:
— If the server has a Microsoft operating system, go to step 3.
— If the server has a Linux operating system, go to step 4.
3. For a Microsoft operating system:
a. Reconnect the SCSI cable from the redundant HBA to the MSA500 system.
b. Cycle the server power.
4. Repeat steps 1 through 3 for subsequent servers.
5. Use the appropriate software for specific Microsoft or Linux multipath
operations:
— For Microsoft operating systems, refer to “Static LUN Balancing” in this
chapter.
— For Red Hat or SuSE Linux operating systems, refer to “Static Load
(Read-Only) Balancing” in this chapter.
— For the UnitedLinux operating system, refer to “UnitedLinux Configuration”
in this chapter.
Commenti su questo manuale