Installation and Operation
HP Smart Array Multipath Software User Guide 2-3
HP CONFIDENTIAL
Writer: Rob Weaver File Name: c-ch2 Installation and Operation.doc
Codename: BorealisII Part Number: 307958-003 Last Saved On: 9/19/03 9:20 AM
1. Uninstall Smart Array Multipath software, if installed. Refer to “Uninstalling
Smart Array Multipath Software Driver” in this chapter.
2. Upgrade to Windows Server 2003.
3. Install Smart Array Multipath software v2.0 or later. Refer to “First-Time
Installation” in this chapter.
Upgrading from v1.0 to v2.0
1. Uninstall Smart Array Multipath software v1.0. Refer to “Uninstalling Smart
Array Multipath Software Driver” in this chapter.
2. Install Smart Array Multipath software v2.0 or later. Refer to “First-Time
Installation” in this chapter.
Uninstalling Smart Array Multipath Software Driver
To uninstall the software:
CAUTION: Before uninstalling the software driver in a Microsoft Windows
Server 2003 clustering environment, use the Cluster Administrator to stop the cluster
service on the appropriate node.
1. Power down the server.
2. Disconnect all SCSI cables from any Smart Array 532 Controllers in the system,
unless the boot drive is attached.
3. Power up the server.
4. Select Start>Settings>Control Panel.
5. Select Add/Remove Programs.
6. From the list of components, select Compaq Smart Array Redundancy Filter
Driver.
NOTE: For Microsoft Windows Server 2003 only, the selection is Compaq Smart Array
Multipath Driver.
7. Click Change/Remove.