
System Preparation
HP Smart Array Multipath Software User Guide 1-13
HP CONFIDENTIAL
Writer: Rob Weaver File Name: b-ch1 System Preparation.doc
Codename: BorealisII Part Number: 307958-003 Last Saved On: 9/19/03 9:20 AM
The raidtab configuration file must reside in the /etc directory. The contents of
/etc/raidtab should resemble the following:
raiddev /dev/md0
raid-level multipath
nr-raid-disks 2
persistent-superblock 1
chunk-size 8
device /dev/cciss/c0d2p1
raid-disk 0
device /dev/cciss/c1d2p1
raid-disk 1
raiddev /dev/md1
raid-level multipath
nr-raid-disks 2
persistent-superblock 1
chunk-size 8
device /dev/cciss/c0d2p2
raid-disk 0
device /dev/cciss/c1d2p2
raid-disk 1
Commenti su questo manuale