Hp StorageWorks Scalable File Share Manuale Utente Pagina 134

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 133
Verifying, diagnosing, and maintaining the system6–4
Table 6-2 lists the components, the component tests, and the level of each test.
severity Specifies the severity levels that are to be reported from the tests. Valid values are
1, 2, 3, 4.
You can use this option to control the report generation and limit the output from
the tests. You can specify one severity level, a comma-separated list of levels, and/
or a range of levels; for example, 1,3-4.
For example, specifying severity=2 limits the reporting to warnings only.
The default is severity=1-3.
report Specifies where the output from the tests is to be directed.
You can use this option to redirect the report to a file.
The default is report=stdout.
Table 6-2 Components, tests, and levels for syscheck command
Component Test Level
firmware Check the firmware version of the BIOS on each server. 1
Check the firmware version of the iLO on each server. 1
Check the firmware version of the 6404 adapter on each
server.
1
Check the firmware version of each SFS20 array. 1
Check the firmware version of InfiniBand HCA adapters. 2
ilo Ping server iLO. 1
interconnect Check that each server has an Elan Network ID set in the
database (Quadrics interconnect only).
2
Check that each server is in the Elan nodeset (Quadrics
interconnect only).
2
Check that each server has a Myrinet Network ID set in the
database (Myrinet interconnect only).
2
Check the state of each interconnect link on the system. 2
network Ping servers on each network. 1
Check that dual Gigabit Ethernet interfaces are correctly
configured.
Also check that the IP address of each interface is unique.
1
Check that the group server(s), if configured, are responding.
Check the performance of the management network adapters
(should be at least 100Mb/sec).
2
Check the performance of the Gigabit Ethernet network
adapters (should be 1000Mb/sec).
2
power Check monitored power state of server. 1
Check power state of server. 2
server Check run state of server. 1
Check configuration state of server. 1
Check fan, power, temperature, DIMM and Integrated
Management Log status of server.
1
Table 6-1 Arguments for the syscheck command
Argument Description
Vedere la pagina 133