Troubleshooting 93
2. Examine all attached SCSI devices.
3. Remove any SE devices found and replace them with LVD devices.
30 I2C Read Failure <I2C device name>
Type: Error
Description: Read access has failed on an internal device on an I2C hardware
bus. Certain I2C devices are considered critical and result in a failure of the
controller while others may result in some loss of functionality (such as lost
display messages).
Action: Replace the device. If this action does not solve the problem, contact HP
support.
31 I2C Write Failure <I2C device name>
Type: Error
Description: Write access has failed on an internal device on an I2C hardware
bus. Certain I2C devices are considered critical and result in a failure of the
controller while others may result in some loss of functionality (such as lost
display messages).
Action: Replace the device. If this action does not solve the problem, contact HP
support.
32 Chassis NVRAM Contents Corrupted
Type: Error
Description: NVRAM is corrupt. The storage system cannot continue to operate.
Action: Contact HP support.