105 Volume #<n> State Expansion Active
Type: Informational
Description: The configured volume is performing a volume expansion
operation.
Action: None
106 Volume #<n> State Waiting to Rebuild
Type: Informational
Description: The configured volume is waiting before rebuilding data on a
physical drive that replaces a previously failed drive. The rebuild may not have
started yet because the controller is already performing a rebuild on another
configured volume.
Action: None
107 Volume #<n> State Waiting to Expand
Type: Informational
Description: The configured volume is waiting to start a volume expansion
operation. The expansion may not have started yet because another configured
volume is undergoing expansion or a rebuild is occurring on the configured
volume.
Action: None