Hp StorageWorks 500 G2 Modular Smart Array Manuale Utente Pagina 127

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 126
Troubleshooting 127
407 Storage Box #<n> Overheated
Type: Error
Description: The temperature sensor in the specified storage system indicates
that the temperature exceeded the normal operating range.
Action:
1. Avoid hardware failure. Power down the storage system (on page 28
).
2. Be sure that all MSA500 G2 storage system fans are operating.
3. Replace any failed fans.
4. Be sure that all bays are populated with components or blanks.
If this action does not solve the problem, contact HP support.
408 Storage Box #<n> Power Supply OK
Type: Informational
Description: The specified storage system indicates that one of its previously
failed power supplies is now operating normally.
Action: None
409 Storage Box #<n> Power Supply Failed
Type: Error
Description: The specified storage system indicates that one of its power
supplies has failed.
Action:
1. Check all power supplies for damage.
2. Replace any failed power supplies.
Vedere la pagina 126
1 2 ... 122 123 124 125 126 127 128 129 130 131 132 ... 152 153

Commenti su questo manuale

Nessun commento