Hp StorageWorks 500 G2 Modular Smart Array Manuale Utente Pagina 109

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 108
Troubleshooting 109
83 Drive Hot Removed Box #<n>, Bay <n>
Type: Informational
Description: A SCSI drive has been removed from the MSA500 G2 storage
system.
Action: None
84 Drive Failure Box #<n>, Bay <n>
Type: Informational
Description: A SCSI drive in the MSA500 G2 storage system has failed. If the
drive was part of a configured volume, the state of the volume depends on the
fault tolerance used.
Action: Replace the failed drive or drives as soon as possible ("Recognizing hard
drive failure" on page 78
).
85 Bad Drive Failure Box #<n>, Bay <n>
Type: Error
Description: A SCSI drive has corrupt firmware. Continued use of this drive
could result in drive failure, decreased performance, or data loss.
Action: Do one of the following:
Update the drive firmware ("Management Agents" on page 60
).
Replace the failed drive or drives as soon as possible ("Recognizing hard
drive failure" on page 78
).
If this action does not solve the problem, contact HP support.
Vedere la pagina 108
1 2 ... 104 105 106 107 108 109 110 111 112 113 114 ... 152 153

Commenti su questo manuale

Nessun commento