116 HP StorageWorks MSA500 G2 Storage System User Guide
113 Volume #<n> Expansion Failure
Type: Error
Description: The volume expansion operation on the configured volume failed.
Action: Run ACU and determine the state of the volume. If the volume is still
operational, reattempt the operation.
114 Volume #<n> State Deleted
Type: Informational
Description: The configured volume is deleted and no longer available. Use
ACU to delete volumes.
Action: None
120 Configured Volumes #<n>
Type: Informational
Description: The controller detected the specified number of configured volumes
at power up.
Action: None
121 No Volumes Detected
Type: Informational
Description: The controller did not detect configured volumes at power up.
Action: If configured volumes are expected at power up:
1. Power down the storage system (on page 28
).