Hp StorageWorks 1510i Modular Smart Array Manuale Utente Pagina 67

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 99
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 66
Setting the pref
erredpathforaLUN(PreferredPath)
NOTE:
This task is available for dual-controller congurations only.
To manually (explicitly) set controller ownership of a LUN:
1. Select an already-congured logical drive from the system component list, and then select the
Preferred Path task.
2. Expand the Preferred Path drop-down box and select a controller.
IMPORTANT:
If the Redundancy Setting mode is set to Automatic”, path ownership may automatically switch
from one controller to the other, depending on the processing load, as the system attempts
to balance the processing load between the two controllers. To permanently set the path for
a LUN, the Redundancy Setting mode must be set to ’Manual”. For more information, see
Disabling auto-path switching (Redundancy Settings)”onpage64.
Viewin
g detailed component information (More Information)
To view
detailed information about a system component, select the desired component, and then select
More Information. The following image illustrates sample information displayed for a target.
HP Storage Management Utility user guide
67
Vedere la pagina 66
1 2 ... 62 63 64 65 66 67 68 69 70 71 72 ... 98 99

Commenti su questo manuale

Nessun commento