Hp StorageWorks 1510i Modular Smart Array Manuale Utente Pagina 31

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 99
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 30
Sample congur
ation—Physical-to-logical storage diagram
15293
1
2
5 6 7
8 9 10
11 12 13
3 4
Item
Description
1
M SA 1510
i controller shelf and
MSA20 st
orage enclosure
Sample includes two array controllers and two 2-Port Ethernet iSCSI modules,
with twelve SATA hard drives in the storage enclosure.
2
Array A
Uses hard drives from bays 1, 2, 3, and 4.
3ArrayB
Uses hard drives from bays 5, 6, and 7, with number 11 assigned as a spare.
4ArrayC
Uses har
ddrivesfrombays8,9,and10,withnumber12assignedasaspare.
5
Logical Drive 1
Uses all space from Array A, with RAID 1+0 fault tolerance.
6
Logical Drive 2
Uses all space from Array B, with RAID 5 fault tolerance.
7
Logical Drive 3
Uses all
space from Array C, with RAID 5 fault tolerance.
8
Mapped Logical Drive 1
When Logical Drive 1 was mapped to this target (Target 1), it was renamed
to Mapped Logical Drive 1.
9
Mapped Logical Drive 1
When Logical Drive 2 was mapped to this target (Target 2), it was renamed
to Mapped Logical Drive 1.
10
Mappe
dLogicalDrive1
When Logical Drive 3 was mapped to this target (Target 3), it was renamed
to Mapped Logical Drive 1.
11 T a r g e t 1
12 Ta rget 2
13 Ta r g e
t3
HP Storage Management Utility user guide