1. In the SMU,selectStorage System > Canonical Target CHAP Settings.
2. Expand the
CHAP State drop-down box and change the setting to Enabled.
NOTE:
If Canonic
al Target CHAP settings have already been entered, the display is contracted
and protected by a gateway check box. To change existing CHAP settings, clear the Use
Existing CHAP Settings check box. The page expands, allowing access to the settings.
3. Enter the CHAP Secret in the provided spaces.
4. On the server, open the iSCSI initiator software utility. Navigate through the iSCSI utility and enter
the same canonical CHAP secret assigned in the SMU.
Setting up target-specic initiator-to-target CHAP authentication
Creating a CHAP secret that is unique for each target in the storage system requires two steps:
Assigning a CHAP secret to each target (Step 1).
EnteringthesameCHAPsecretintheiSCSIinitiatorsoftware(Step 4).