Hp VMA-series Memory Arrays Manuale Utente Pagina 246

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 265
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 245
246 HP VMA SAN Gateway Users Guide AM456-9026A
PSU States
To query the state of the power supplies in the system:
Temperatures: per VIMM and Chassis
The following is an example of a query of the temperatures (reported in degrees celsius) of the
chassis and the VIMMs:
snmpwalk -Ou -M +. -m +./VIOLIN-MEMORY-MIB.txt -v 2c -c public ib-srv1
violin-memory | grep -i psu
enterprises.violin-
memory.products.memoryGateway.appliance.media.chassisSystemArrayTable.
chassisSystemArrayEntry.chassisSystemPowerPSUA."vmem-array-098" =
STRING: "ON"
enterprises.violin-
memory.products.memoryGateway.appliance.media.chassisSystemArrayTable.
chassisSystemArrayEntry.chassisSystemPowerPSUB."vmem-array-098" =
STRING: "ON"
[myvmem@ib-cn2 mibs]$
[myvmem@lib-cn2 mibs]$ snmpwalk -Ou -M +. -m +./VIOLIN-MEMORY-MIB.txt -
v 2c -c public ib-srv1 violin-memory | grep -i temp
enterprises.violin-
memory.products.memoryGateway.appliance.media.arrayVimmTable.arrayVimm
Entry.temp."vmem-array-098"."vimm00" = INTEGER: 39
enterprises.violin-
memory.products.memoryGateway.appliance.media.arrayVimmTable.arrayVimm
Entry.temp."vmem-array-098"."vimm01" = INTEGER: 43
enterprises.violin-
memory.products.memoryGateway.appliance.media.arrayVimmTable.arrayVimm
Entry.temp."vmem-array-098"."vimm02" = INTEGER: 43
enterprises.violin-
memory.products.memoryGateway.appliance.media.arrayVimmTable.arrayVimm
Entry.temp."vmem-array-098"."vimm03" = INTEGER: 45
enterprises.violin-
memory.products.memoryGateway.appliance.media.arrayVimmTable.arrayVimm
Vedere la pagina 245
1 2 ... 241 242 243 244 245 246 247 248 249 250 251 ... 264 265