Vedere la pagina 68
show perf start perf
stop perf clear perf
show cacheinfo show taskstats
set debug show eventlog
Example help add unit command and response
CLI> help add unit
Usage: ’add unit <#> raid_level=R
data=diskrange
[spare=diskrange]
[stripe_size=S]
[size=X<GB|MB>]
[max_boot=<enable/disable>]
[cache=<enable/disable>]
#={0-31} / R={0,1,5,6(ADG)} / X={positive integer} / S={8,16,32,64,128,256}
diskrange examples: DISK101
DISK101-DISK105
"DISK101 DISK112-DISK202 DISK314"
DISKxyy: x={1,2,3} (box #) / yy={01-14} (bay #)
ex: DISK111 - disk in box 1, bay 11
max_boot is enabled by default. it can be disabled for OS’s that don’t
support the creation of bootdrives > 4GB
cache is enabled by default. enables/disables cache for the new unit.
add unit creates a new logical unit using the specified settings
newpage pi
1510i Modular Smart Array Command Line Interface user guide
69
Vedere la pagina 68
1 2 ... 64 65 66 67 68 69 70 71 72 73 74 ... 153 154

Commenti su questo manuale

Nessun commento