Hp Array Controller HSG V8.7 Software Manuale Utente Pagina 124

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 206
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 123
Single-Ended I/O Module
5–22 UltraSCSI RAID Enclosure
Table 5–10 Installing an I/O Module
1. Verify that the I/O
module being installing is
a model
DS–BA35X–MN.
Note
Jumpers are factory installed—do not modify jumper settings.
2. Align the cable with the
left
I/O module connector.
Gently insert the cable
connector into the module
connector. Tighten both
cable connector thumb
screws to fully seat the
connector.
3. Install a wire tie through the holes on the cable support bracket and
around the cable. Tighten the wire tie.
4. If attaching a cable to the
right
I/O module connector is necessary,
repeat steps 2 and 3 using the
right
I/O module connector.
5. Align the I/O module with the backplane connector in the enclosure
shroud. Gently insert the module and fully seat it. Use a screwdriver
to tighten the spring-loaded mounting screws.
6. Turn O
N
the subsystem using Table 5–7 and verify that it is operating
properly.
CXO5816A
CXO5940A
Vedere la pagina 123