HP ProLiant WS460c Gen8 Graphics Server
Blade and Expansion Blade
User Guide
Abstract
This guide provides operation information for the HP ProLiant WS460c Gen8 Graphics Server Blade and Expansion Blade. This guide is for
technicians that install, administer, and troubleshoot servers and storage systems.
Part Number: 703968-004
February 2014
Edition: 4
Vedere la pagina 0
1 2 3 4 5 6 ... 97 98

Sommario

Pagina 1 - User Guide

HP ProLiant WS460c Gen8 Graphics Server Blade and Expansion Blade User Guide Abstract This guide provides operation information for the HP ProLiant

Pagina 2

Component identification 10 Item LED Status Definition Flashing amber The drive is not configured and predicts the drive will fail. Solid

Pagina 3 - Contents

Component identification 11 System maintenance switch Position Default Function S1 Off Off = iLO 4 security is enabled. On = iLO 4 security is d

Pagina 4 - Contents 4

Component identification 12 The arrow points to the front of the workstation blade. DIMM tool location The DIMM tool is used to open and close an

Pagina 5 - Contents 5

Component identification 13 Item Connector Description 2 Video For connecting a video monitor 3 USB For connecting up to two USB devices 4 Seri

Pagina 6 - Component identification

Operations 14 Operations Power up the workstation blade The Onboard Administrator initiates an automatic power-up sequence when the workstation blad

Pagina 7 - Front panel LEDs and buttons

Operations 15 This command initiates a controlled shutdown of applications and the OS before the workstation blade enters standby mode. o poweroff

Pagina 8 - Item Description Status

Operations 16 Remove the access panel 1. Power down the workstation blade (on page 14). 2. Remove the workstation blade (on page 15). 3. If neces

Pagina 9

Operations 17 Remove the DIMM baffle 1. Power down the workstation blade (on page 14). 2. Remove the workstation blade (on page 15). 3. Remove th

Pagina 10 - System board components

Operations 18 o DIMM baffle (right side) Remove the SAS controller 1. Power down the workstation blade (on page 14). 2. Remove the workstation b

Pagina 11 - DIMM slot locations

Operations 19 5. Remove the SAS controller. Install the SAS controller 1. Power down the workstation blade (on page 14). 2. Remove the workstati

Pagina 12 - HP c-Class Blade SUV Cable

© Copyright 2012, 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only war

Pagina 13 - Item Connector Description

Operations 20 5. Close the SAS controller handle and then install the SAS controller. To properly seat the SAS controller, press firmly in the areas

Pagina 14 - Operations

Operations 21 Remove the WS460c Graphics Expansion Blade 1. Power down the workstation blade (on page 14). 2. Remove the workstation blade. 3. Re

Pagina 15 - Remove the workstation blade

Operations 22 pass-through mezzanine card is used. Retain unused stabilizer/coupler for future use with possible configuration changes. 6. Disconne

Pagina 16 - Install the access panel

Operations 23 8. Remove the screws (1), slide the graphics expansion blade back, and then lift it up (2) from the workstation blade. Remove the WS

Pagina 17 - Remove the DIMM baffle

Operations 24 5. Remove the gasket. 6. Disconnect the power cable from the upper mezzanine card, and then disconnect the other end of the power ca

Pagina 18 - Remove the SAS controller

Operations 25 b. Disconnect the other end of the signal cable (4). 8. Remove the retaining block.

Pagina 19 - Install the SAS controller

Operations 26 9. Remove the anchoring pin from the graphics expansion blade, and then remove the card cage. To reinstall the component, reverse the

Pagina 20

Operations 27 6. Remove the graphics card from the bottom slot of the card cage. 7. Install the new graphics card to the bottom slot of the card c

Pagina 21

Operations 28 Install the NVIDIA Quadro K5000 or K6000 graphics card Required tools for this procedure: • T-10/T-15 Torx screwdriver (provided insi

Pagina 22

Operations 29 3. Remove the screws and washers. IMPORTANT: Remove the I/O plate from the original NVIDIA GRID K2 card. Before installing the NV

Pagina 23

Contents 3 Contents Component identification ...

Pagina 24

Operations 30 If the screws lack Nylok coating or are used, add Loctite 242 Threadlocker 3~5 threads from the tip. 6. Install M2.5x6 mm wafer head

Pagina 25 - Remove the retaining block

Operations 31 7. Torque both front plate screws to 3.0~3.5 in-lbf. IMPORTANT: Ensure that air flow impedance control labels cover the three ope

Pagina 26

Operations 32 For software installation information, see the Microsoft Windows on HP ProLiant WS460c Gen8 Workstation Blade with WS460c Graphics Exp

Pagina 27

Operations 33 To remove the graphics cards from the graphics expansion blade and install the plate: 1. Power down the workstation blade (on page 14

Pagina 28

Operations 34 5. Install M2.5x6 mm wafer head screw through the plate tab and process control board hole alignment to the baseplate, and then tor

Pagina 29 - Operations 29

Operations 35 6. Torque the three front plate screws to 3.0~3.5 in-lbf. IMPORTANT: Ensure that air flow impedance control labels cover the five

Pagina 30 - Operations 30

Operations 36 • T-10/T-15 Torx screwdriver (provided inside the server) • HP Insight Diagnostics software For basic installation instructions, fol

Pagina 31

Setup 37 Setup Overview Installation of a workstation blade requires the following steps: 1. Install and configure an HP BladeSystem c-Class enclos

Pagina 32

Setup 38 Interconnect bay numbering and device mapping • HP BladeSystem c7000 Enclosure To support network connections for specific signals, insta

Pagina 33

Setup 39 • HP BladeSystem c3000 Enclosure and Tower Enclosure Server blade signal Interconnect bay number Interconnect bay label Notes Flex

Pagina 34 - Operations 34

Contents 4 Memory options ...

Pagina 35

Setup 40 Two types of interconnect modules are available for HP BladeSystem c-Class enclosures: Pass-Thru modules and switch modules. For more infor

Pagina 36

Setup 41 2. Remove the enclosure connector cover. 3. Install the workstation blade. Completing the configuration To complete the workstation bla

Pagina 37 - Overview

Hardware options installation 42 Hardware options installation Introduction If more than one option is being installed, read the installation instru

Pagina 38

Hardware options installation 43 3. Install the drive. 4. Determine the status of the drive from the drive LED definitions ("Hot-plug drive L

Pagina 39 - Connecting to the network

Hardware options installation 44 6. Remove the heatsink blank. Retain the heatsink blank for future use. 7. Open each of the processor locking lev

Pagina 40 - Installing a server blade

Hardware options installation 45 8. Remove the clear processor socket cover. Retain the processor socket cover for future use. 9. Install the proc

Pagina 41 - Completing the configuration

Hardware options installation 46 CAUTION: Do not press down on the processor. Pressing down on the processor may cause damage to the processor s

Pagina 42 - Drive option

Hardware options installation 47 CAUTION: Heatsink retaining screws should be tightened in diagonally opposite pairs (in an "X" pattern)

Pagina 43 - Processor option

Hardware options installation 48 • Quad-rank PC3L-10600 (DDR3-1333) LRDIMMs operating at up to 1333 MT/s Speed, voltage, and capacity DIMM type D

Pagina 44

Hardware options installation 49 Channel Slot Slot number 1 A E 1 2 2 B F 3 4 3 C G 8 7 4 D H 6 5 For the location of the slot numbers, see &qu

Pagina 45

Contents 5 HP Technology Service Portfolio ... 78

Pagina 46

Hardware options installation 50 DIMM identification To determine DIMM characteristics, use the label attached to the DIMM and the following illustr

Pagina 47 - Memory options

Hardware options installation 51 • Online spare memory—provides protection against failing or degraded DIMMs. Certain memory is reserved as spare,

Pagina 48 - HP SmartMemory

Hardware options installation 52 the memory contents of the degraded rank to the online spare rank. The workstation blade then deactivates the faili

Pagina 49

Hardware options installation 53 o LRDIMMs are treated as dual-rank DIMMs. Lockstep Memory population guidelines For Lockstep memory mode configura

Pagina 50 - Memory configurations

Hardware options installation 54 7. Install the DIMM. 8. Install all DIMM baffles. 9. Install the access panel (on page 16). To configure the mem

Pagina 51

Hardware options installation 55 4. Remove the mezzanine assembly from the workstation blade. 5. Align the mezzanine card with the guide pins on t

Pagina 52 - Online spare population

Hardware options installation 56 6. Install the mezzanine card in the mezzanine assembly, and then tighten the mezzanine card screws to secure the c

Pagina 53 - Installing a DIMM

Hardware options installation 57 IMPORTANT: This procedure is for replacing NVIDIA Quadro 1000M and 3000M graphics cards only on the workstation b

Pagina 54 - Mezzanine card option

Hardware options installation 58 To install the mezzanine card: 1. Align the mezzanine card with the guide pins on the mezzanine assembly. 2. Ins

Pagina 55

Hardware options installation 59 o FBWC capacitor pack for the SAS controller o FBWC capacitor pack for a mezzanine option. 5. Route the FBWC ca

Pagina 56

Component identification 6 Component identification Front panel components Item Description 1 Hard drive bay 1 2 Server blade release button 3

Pagina 57

Hardware options installation 60 o Route the cable along the right DIMM baffle and connect the cable to the SAS controller. o Route the cable alon

Pagina 58 - FBWC capacitor pack

Hardware options installation 61 When installing or replacing a TPM, observe the following guidelines: • Do not remove an installed TPM. Once insta

Pagina 59

Hardware options installation 62 9. Install the TPM board. Press down on the connector to seat the board ("System board components" on pag

Pagina 60

Hardware options installation 63 To help ensure maximum security, observe the following guidelines when retaining the recovery key/password: • Alwa

Pagina 61

Cabling 64 Cabling Cabling resources Cabling configurations and requirements vary depending on the product and installed options. For more informati

Pagina 62

Cabling 65 Connecting locally to a server blade with video and USB devices Use the SUV cable to connect a monitor and any of the following USB devic

Pagina 63

Cabling 66 Accessing local media devices Use the following configuration when configuring a workstation blade or loading software updates and patche

Pagina 64 - Cabling

Troubleshooting 67 Troubleshooting Troubleshooting resources The HP ProLiant Gen8 Troubleshooting Guide, Volume I: Troubleshooting provides procedur

Pagina 65 - USB devices

Software and configuration utilities 68 Software and configuration utilities Server mode The software and configuration utilities presented in this

Pagina 66

Software and configuration utilities 69 iLO 4 enables and manages the Active Health System (on page 69) and also features Agentless Management. All

Pagina 67 - Troubleshooting

Component identification 7 Front panel components for workstation blade with graphics expansion blade Item Description 1 Serial label pull tab 2

Pagina 68 - HP iLO Management

Software and configuration utilities 70 The data that is collected is managed according to the HP Data Privacy policy. For more information see the

Pagina 69 - Active Health System

Software and configuration utilities 71 see the Resources tab on the HP website (http://www.hp.com/go/ilo). For consolidated drive and firmware upda

Pagina 70 - Intelligent Provisioning

Software and configuration utilities 72 Scripting Toolkit for Windows and Linux The Scripting Toolkit for Windows and Linux is a server deployment p

Pagina 71 - HP Insight Diagnostics

Software and configuration utilities 73 • Displaying system information • Selecting the primary boot controller • Configuring memory options • L

Pagina 72 - HP ROM-Based Setup Utility

Software and configuration utilities 74 For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or the H

Pagina 73 - Auto-configuration process

Software and configuration utilities 75 Warning: The Product ID should ONLY be modified by qualified service personnel. This value should always mat

Pagina 74 - Configuring AMP modes

Software and configuration utilities 76 For more information about the storage controller and its features, select the relevant controller user docu

Pagina 75 - Utilities and features

Software and configuration utilities 77 USB support HP provides both standard USB 2.0 support and legacy USB 2.0 support. Standard support is provi

Pagina 76 - Automatic Server Recovery

Software and configuration utilities 78 If you are installing drivers from SPP, be sure that you are using the latest SPP version that your workstat

Pagina 77 - Keeping the system current

Software and configuration utilities 79 hardware, HP resolves the problem according to service level commitments. If the reported incident is relate

Pagina 78 - ProLiant servers

Component identification 8 Item Description Status bar Flashing Green = Power On/Standby button service is being initialized Flashing Amber = Deg

Pagina 79

Battery replacement 80 Battery replacement If the workstation blade no longer automatically displays the correct date and time, then replace the bat

Pagina 80 - Battery replacement

Regulatory information 81 Regulatory information Safety and regulatory compliance For safety, environmental, and regulatory information, see Safety

Pagina 81 - Regulatory information

Electrostatic discharge 82 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions yo

Pagina 82 - Electrostatic discharge

Specifications 83 Specifications Environmental specifications Specification Value Temperature range* — Operating 10°C to 35°C (50°F to 95°F) Non-

Pagina 83 - Specifications

Support and other resources 84 Support and other resources Before you contact HP Be sure to have the following information available before you call

Pagina 84 - Support and other resources

Support and other resources 85 providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship

Pagina 85

Support and other resources 86 Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'in

Pagina 86 - Customer Self Repair

Support and other resources 87 HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen,

Pagina 87

Support and other resources 88 sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de componentes

Pagina 88 - Reparo feito pelo cliente

Support and other resources 89 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pel

Pagina 89

Component identification 9 Item Description Status power LED pressed. Solid Amber = System is in standby; Power On/Standby button service is init

Pagina 90

Support and other resources 90

Pagina 91

Support and other resources 91

Pagina 92 - Acronyms and abbreviations

Acronyms and abbreviations 92 Acronyms and abbreviations ABEND abnormal end ACU Array Configuration Utility ADM Advanced Data Mirroring AMP Advan

Pagina 93

Acronyms and abbreviations 93 LV DIMM low-voltage DIMM ORCA Option ROM Configuration for Arrays POST Power-On Self Test PXE preboot execution env

Pagina 94 - Documentation feedback

Documentation feedback 94 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentat

Pagina 95 - Index 95

Index 95 A access panel 16 ACU (Array Configuration Utility) 68, 75 Advanced ECC memory 51, 52, 74 Array Configuration Utility (ACU) 75 ASR

Pagina 96 - Index 96

Index 96 G graphics expansion blade removal 21, 23 grounding methods 82 H hard drive backplane connector 10 hard drive bays 6, 7 hard drive

Pagina 97 - Index 97

Index 97 NVIDIA Tesla K20X graphics card 35 O operating systems 78 operations 14 Option ROM Configuration for Arrays (ORCA) 68, 76 options i

Pagina 98 - Index 98

Index 98 V VCA (Version Control Agent) 78 VCRM (Version Control Repository Manager) 78 Version Control Agent (VCA) 78 Version Control Reposito

Commenti su questo manuale