2. See Table 5, page 30 for a description of the error code.
For details about the error codes that are not described in Table 5, page 30, contact your HP
Service Representative (see Calling HP Technical Support).
Table 5 Error Codes and Error Contents When Using RAID Manager
DescriptionError Code (SSB2)Error Code (SSB1)
The setting failed because the specified volume does not
exist.
B9BDB9BF/B9BD
The specified volume is a command device.B9C2
The command was rejected due to one of the following
reasons:
B9C4
• The specified volume is a P-VOL or S-VOL of XP Snap-
shot
• The specified volume is a virtual volume.
• The specified volume is a pool volume.
• The specified volume is an S-VOL of XP XP Continuous
Access Journal.
• The specified volume is a journal volume.
• The specified volume is reserved for the XP Auto LUN
function.
• The specified volume is a P-VOL or S-VOL of XP XP
Business Copy.
• The consumed capacity exceeded the licensed capacity.
• The access attribute cannot be changed because the
data retention term is set.
• The specified volume is a command device.
• The specified volume is in the PAIR or COPY status.
• The specified volume does not exist.
• The S-VOL Disable attribute is set to the specified
volume.
• The reserve function cannot be canceled by RAID
Manager.
The Data Retention Utility is not installed.B9C7
The consumed capacity exceeded the licensed capacity.B9C9
Either:
B9CA
• More than 60 years are set as the data retention days,
or
• The other interface updated the settings while the Data
Retention Utility was changing the settings (Java conflic-
ted with the other interface).
The data retention term cannot be set because the access
attribute is set to Read/Write.
B9CB
Troubleshooting30