Hp 3PAR Operating System Software Manuale Utente

Navigare online o scaricare Manuale Utente per Magazzini Hp 3PAR Operating System Software. HP 3PAR Operating System Software User Manual [en] [de] [es] [fr] Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 424
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
HP 3PAR Management Console
User Guide
Abstract
The HP 3PAR Management Console and the topics in this Help system are for use by system and storage administrators who
monitor and direct system configurations and resource allocation for HP 3PAR Storage Systems.
HP Part Number: QL226-96337
Published:December 2012
Vedere la pagina 0
1 2 3 4 5 6 ... 423 424

Sommario

Pagina 1 - HP 3PAR Management Console

HP 3PAR Management ConsoleUser GuideAbstractThe HP 3PAR Management Console and the topics in this Help system are for use by system and storage admini

Pagina 2

Configuring 1-to-1 Remote Copy...189Targets...

Pagina 3 - Contents

The following information is provided on the Active VLUNs tab:DescriptionColumnThe exported LUN value. Each LUN is a link to the “Active VLUNs Tab” (p

Pagina 4 - 4 Contents

1. In the Manager pane, click Hosts.2. In the Management tree, click Unassigned under the Paths node of the system that containsthe unassigned host pa

Pagina 5 - Contents 5

8 Managing Host SetsHost sets allow users to create a name for a group of hosts. This allows a virtual volume to beexported to the same set of hosts.W

Pagina 6 - 6 Contents

3. Click the Hosts tab in the Hosts screen.4. Select the host(s) you wish to add.5. Right-click and then click Add to Host Set in the menu that appear

Pagina 7 - Contents 7

2. In the Management tree, click Host Sets under the Hosts node for system that contains the hostsets you wish to view.The following information is pr

Pagina 8 - 8 Contents

The following information is provided:DescriptionFieldGroupThe host set name.NameGeneralThe domain in which the host set resides.DomainThe number of h

Pagina 9 - Contents 9

The Descriptors FilterFor each host listed, the Descriptors screen displays the information entered in the Location, IPAddress, Operating System, Mode

Pagina 10 - 10 Contents

9 Managing Common Provisioning GroupsThe Provisioning Manager allows you to perform all tasks associated with system CommonProvisioning Groups (CPGs),

Pagina 11 - Contents 11

12. Growth Increment* - Click the Enabled checkbox, enter the appropriate value, and click theunit list (MiB, GiB, TiB)13. Growth Limit* - Click the E

Pagina 12 - 12 Contents

the step size defaults to 32 KiB for RAID 0 and RAID 1, and 64 KiB for RAID 5. For RAID 6,the default is a function of the set size.9. Growth Incremen

Pagina 13 - Contents 13

Revert Remote Copy Groups...208Recover Remote Copy Groups...

Pagina 14 - 14 Contents

2. In the General group box:a. In the Include default value column on the left, check the appropriate boxes to includeproperties in the template. The

Pagina 15 - Contents 15

2. Use the following table as a guide when choosing which properties to include in a CPGtemplate, Allocation Settings screen:Include in the template i

Pagina 16 - 16 Contents

8. From the Preferred Chunklets* list, select Fast (default) or Slow.9. RAID Type - Select the RAID type for the volume.10. Set Size - Select the set

Pagina 17 - “Managing Ports” (page 20)

2. Right-click the CPG you wish to remove.3. In the menu that appears, click Remove.The Remove CPG dialog box appears.4. Click OK.Creating Common Prov

Pagina 18 - 1 Connecting to Systems

2. In the General group box:a. In the Include default value column on the left, check the appropriate boxes to includeproperties in the template. The

Pagina 19 - The System Dashboard 19

2. Use the following table as a guide when choosing which properties to include in a CPGtemplate, Allocation Settings screen:Include in the template i

Pagina 20 - 2 Managing Ports

2. In the General group box:a. In the Include default value column on the left, check the appropriate boxes to includeproperties in the template. The

Pagina 21 - Configuring Ports 21

2. Use the following table as a guide when choosing which properties to include in a CPGtemplate, Allocation Settings screen:Include in the template i

Pagina 22 - Configuring iSCSI Ports

The following information is displayed:DescriptionFieldGroupThe total number of CPGs.CPGsGeneralThe total number of Fast Class (FC) drives.FCThe total

Pagina 23 - Configuring Ports 23

2. In the Management Window, click the CPGs tab.The CPGs tab presents information in a list pane and a detail pane.“List Pane” (page 119)“Detail Pane”

Pagina 24 - Setting a Port Offline

Security & Domains Node Domains Tab...251Security & Domains Node Domain Sets

Pagina 25 - Issuing an LIP Command

The following information is displayed:DescriptionColumnThe CPG name.NameThe domain to which the CPG belongs.DomainThe state of the CPG.StateThe RAID

Pagina 26 - Viewing System Ports

The following information is displayed:DescriptionsColumnThe CPG name.NameThe domain to which the CPG belongs.DomainThe state of the CPG.StateThe RAID

Pagina 27

Displaying Raw Capacity InformationTo view raw capacity information, select Raw Capacity from the filtering list.The following information is displaye

Pagina 28

DescriptionColumnThe CPG name.NameThe domain to which the CPG belongs.DomainThe state of the CPG.StateThe percentage of used copy space which results

Pagina 29 - Viewing System Ports 29

Summary TabThe following information is displayed on the Summary tab:DescriptionFieldGroupThe Common Provisioning Group's(CPG's) name.NameGe

Pagina 30 - 30 Managing Ports

DescriptionFieldGroupDisplays mapped and unmapped allocated space.AllocatedDisplays the distribution of mapped space.Mapped SpaceSettings TabThe follo

Pagina 31

DescriptionFieldGroupNOTE: The Device RPM number does not represent a rotational speed for the driveswithout spinning media (SSD). It is meant as a ro

Pagina 32

DescriptionColumnSpeed of the specified disk.Device RPMNOTE: The Device RPM number does not represent a rotational speed for the driveswithout spinnin

Pagina 33 - Physical Disks

Layout TabThe Layout tab displays which chunklets are used by the selected CPG.NOTE: The Layout tab only appears if you have set your preferences in t

Pagina 34

10 Virtual VolumesThe Provisioning Manager allows you perform various tasks related to virtual volumes. Refer to thefollowing sections for more inform

Pagina 35 - Viewing CNA Ports

Viewing Controller Node Microcontroller Unit Details...294Viewing Controller Node Fans Details...

Pagina 36

a. Select how the volume will be provisioned. Selecting Thinly Provisioned results in thecreation of a Thinly Provisioned Virtual Volume (TPVV). Selec

Pagina 37

2. In the Geometry group box:a. Enter the number of sectors per track, or accept the default value.b. Enter the number of heads per cylinder, or accep

Pagina 38 - Fibre Channel Summary

1. In the Policies group box enable any of the following:a. Allow stale snapshots.b. Restrict export to one host.c. Retention Time. If enabled, enter

Pagina 39

c. If you selected Thinly Provisioned:i. User CPG - Select a user CPG from the CPG list.ii. Copy CPG - Select a copy CPG or <none>.iii. In the A

Pagina 40

2. You may start the Create VV Template wizard using one of the following methods:Method 1 –In the Main Menu Bar, click Actions > Provisioning >

Pagina 41 - Viewing System RCFC Ports

Policies and Geometry1. In the Policies group box:a. In the Include default value column on the left, check the appropriate boxes to includeproperties

Pagina 42

Groups1. In the Source group:a. System - Select the primary (source) system on which the Remote Copy group will becreated.b. (Optional) Domain - Selec

Pagina 43 - RCFC Port Summary

Adding a Virtual Volume to a Remote Copy GroupNOTE: HP 3PAR Remote Copy Software requires an HP 3PAR Remote Copy Software license.For additional infor

Pagina 44

3. Select Scan Only, Offline and Scan, or Scan and Repair.Scan Only – Validates the administration information while the volumes are online.Offline an

Pagina 45 - Viewing System iSCSI Ports

4. (Optional) Select to remove volumes and descendents without active VLUNs, associated withinactive VLUNs, and from volume sets.When the volumes to b

Pagina 46

Alerts Tab...33224 Managing Data Alloca

Pagina 47 - Viewing System RCIP Ports

If you click Yes, the VLUNs will be removed along with the VVs after you click OK in the nextstep.5. Click OK to remove the virtual volume(s).See also

Pagina 48

3. In the menu that appears, click Rollback Tune.4. Click Yes.Managing Virtual Volume SetsWhen working with virtual volume sets, you can:“Creating Vir

Pagina 49 - Viewing SAS Details

2. Comments - Enter any notes about the virtual volume set.3. Click Next to assign/unassign virtual volumes to/from the set.Volumes1. To assign availa

Pagina 50 - Summary Information

d. If Show advanced options is selected, you have the option of selecting the After Export,issue VLUN change notification (LIP or RSCN) checkbox.4. Cl

Pagina 51

DescriptionColumnThe number of virtual volumes belonging to the virtual volume set.Virtual VolumesThe size of the volume in GiB.Virtual SizeThe total

Pagina 52 - Viewing System Port Alerts

2. In the User Space group box:a. In the Include default value column on the left, check the appropriate boxes to includeproperties in the template. T

Pagina 53

Policies and Geometry1. In the Policies group box:a. In the Include default value column on the left, check the appropriate boxes to includeproperties

Pagina 54 - Part II Managing Security

• Disk pattern• RAID• Set size• Row size• Step size• Availability• Preferred chunkletsIf the existing template contains user and copy CPGs from differ

Pagina 55 - Viewing Users

3. In the Copy Space group box:a. In the Include default value column on the left, check the appropriate boxes to includeproperties in the template. T

Pagina 56 - Editing Users

d. Use the following table as a guide when choosing which properties to include in a VVtemplate, Geometry group box:Include in the template in order t

Pagina 57 - Managing User Connections

28 Tuning the System...360Tune System...

Pagina 58 - Removing User Connections

Unexporting Virtual VolumesTo unexport a volume, access the Virtual Volumes tab1. Access the Virtual Volumes tab.2. Right-click on the name of the vol

Pagina 59 - Creating Domains

The Convert Virtual Volume wizard is accessible through the In the Main Menu Bar (click Actions> Performance > Edit Chart), through the Convert

Pagina 60 - Viewing Domains

11 Viewing Virtual VolumesTo view a system's virtual volumes:1. In the Manager Pane, click Provisioning.2. In the Management Tree, click Virtual

Pagina 61

The following information is displayed:DescriptionFieldGroupThe total number of virtual volumes.Virtual VolumesGeneralThe total number of base volumes

Pagina 62 - Viewing the Domains Tab

The following information is displayed:DescriptionColumnThe volume name. Volume tree depth in parenthesis.NameThe domain to which the virtual volume b

Pagina 63

DescriptionColumnThe name of the Common Provisioning Group (CPG) used for user space.User CPGThe name of the Common Provisioning Group (CPG) used for

Pagina 64 - Raw Capacity Information

Displaying Raw Capacity InformationTo view raw capacity information, select Raw Capacity from the filtering list. The raw capacityinformation appears.

Pagina 65 - Creating Domain Sets

The following information is displayed:DescriptionColumnThe volume name. Volume tree depth in parenthesis.NameThe name of the domain.DomainThe state o

Pagina 66 - Viewing Domain Sets

Displaying Space History InformationTo view Space History information, select Space History from the filtering list.The following information is displ

Pagina 67

Summary TabThe following information is displayed in the detail pane's Summary tab:DescriptionFieldGroupThe virtual volume's name.NameGenera

Pagina 68 - Viewing Summary Information

Security & Domains Manager...403Hardware Inventory Manager...

Pagina 69 - Removing Domain Sets

DescriptionFieldGroupSelect the device type, Fast Class (FC), Near Line (NL), or SolidState Device (SSD). The capacity and capacity usage of theselect

Pagina 70 - Associated Objects

DescriptionFieldGroupThe disk type, Fast Class (FC), Nearline(NL), or Solid State (SSD).Device TypeUser Space AllocationThe speed of the disk.Device R

Pagina 71 - Configuring LDAP

DescriptionFieldGroupNOTE: The Device RPM number does not represent a rotational speed forthe drives without spinning media (SSD). It is meant as a ro

Pagina 72

Logical Disks TabThe following information appears in the detail pane's Logical Disks tab:DescriptionColumnThe name of the logical disk.NameThe d

Pagina 73 - Configuring LDAP 73

The following information is displayed in the SCSI-2 Reservations tab (click the Get Data button toretrieve data):DescriptionColumnThe domain to which

Pagina 74 - Viewing an LDAP Configuration

VLUN Templates TabThe following information is displayed in the VLUNs Templates tab:DescriptionColumnThe exported Logical Unit Number (LUN) value.LUNT

Pagina 75 - The LDAP Summary Screen

DescriptionColumnThe name of the host to which the VLUN is exported.HostThe Storage Server port on which the VLUN is exported.PortThe WWN or iSCSI nam

Pagina 76

Hosts TabThe following information is displayed:DescriptionColumnThe volume name.NameThe domain the host is connected to.DomainThe number of ports the

Pagina 77

Alerts TabThe Alerts tab displays a table containing alert information for a single volume selected from thelist pane. The information displayed is id

Pagina 78 - The LDAP Authorization Screen

12 Managing VLUNsWhen working with VLUNs, the following actions are available:“Exporting VLUNs” (page 169)“Removing VLUNs” (page 169)“Viewing VLUNs” (

Pagina 79 - Adding Authorizations

Part I Connecting to the SystemThis part contains information on connecting to the HP 3PAR StoreServ Storage System, managing users,configuring and ma

Pagina 80 - Removing Authorizations

VLUN Templates TabThe VLUN Templates tab is split into a list pane and a detail pane. The list pane displays summaryinformation about system VLUN temp

Pagina 81 - 6 The Security Manager

Displaying Summary InformationThe following information is displayed on the Active VLUNs tab:DescriptionColumnThe exported Logical Unit Number (LUN) v

Pagina 82

DescriptionColumnThe VLUN RAID type.RAID TypeThe name of the host to which the VLUN is exported.HostThe system port on which the VLUN is exported, in

Pagina 83 - Part III Creating Storage

Managing AO ConfigurationAdaptive Optimization (AO) makes it possible to perform cost and performance optimization bymigrating busy regions to higher

Pagina 84 - 7 Managing Hosts

4. Select a performance Mode from the list. The options are as follows:• Performance – Moves more data to the high-performance tier.• Balanced – Moves

Pagina 85 - Editing Hosts

Editing an AO ConfigurationTo edit an existing AO configuration:1. Access the AO Configurations tab in the Management Window.2. Right-click on the nam

Pagina 86 - Fibre Channel

The list pane displays the names of all AO configurations on the selected system and relatedinformation:DescriptionColumnThe name of the AO Configurat

Pagina 87 - Viewing Hosts

DescriptionFieldGroupThe latest running time from this AO configuration's scheduledtasksLast Running TimeThe CPG used for the tier.CPGTier 0/Tier

Pagina 88

DescriptionFieldGroupThe node component for which the alert was generated.ComponentThe number of times the AO configuration task has been run.Repeat C

Pagina 89

Part IV Creating BackupThis part contains information on creating copies and using the remote copy manager.“Creating Copies” (page 180)“Configuring an

Pagina 90 - Viewing Host Information

1 Connecting to SystemsThe HP 3PAR Management Console allows authorized users to connect to a single system, or tomultiple systems. In order to connec

Pagina 91 - Host Explorer Tab

13 Creating CopiesThe HP 3PAR Management Console allows you to create virtual copy snapshots, as well as physicalcopies of base volumes. A physical co

Pagina 92 - Host Summary Details

Creating a Virtual CopyTo create a virtual copy:1. In the Manager Pane, click Provisioning.2. In the Common Actions Panel, click Create Virtual Copy.T

Pagina 93 - Host Explorer Details

Removing a Virtual CopyTo remove a virtual copy:1. Access the Virtual Volumes tab.2. Right-click the virtual copy you wish to remove.3. In the menu th

Pagina 94 - VLUN Details

3. Click Next.The Configure Virtual Copies page appears.Configure Virtual Copies1. If you wish to modify the name of a copy, double-click any name in

Pagina 95 - Active VLUNs

3. Right-click the selected volumes.4. In the menu that appears, click Create Batch Virtual Copy.The Create Batch Virtual Copies dialog box appears.5.

Pagina 96 - Virtual Volumes Details

See “Viewing the Virtual Volumes Tab” (page 153).Creating a Physical CopyTo create a physical copy:1. In the Manager Pane, click Provisioning.2. In th

Pagina 97 - Link Errors Details

Creating a Consistency Group Physical CopyTo create a consistency group physical copy:1. Access the Virtual Volumes tab.2. Select two or more virtual

Pagina 98 - Viewing Paths

Resynchronizing a Physical CopyTo resynchronize a physical copy:1. Access the Virtual Volumes tab.2. Right-click the physical copy you wish to resynch

Pagina 99

14 Configuring and Managing Remote CopyThe Remote Copy Manager of the HP 3PAR Management Console allows you to create and manageHP 3PAR Remote Copy co

Pagina 100 - Viewing Unassigned Paths

2. In the Common Actions Panel, click Configure RC Port.The <Port Type> Configuration dialog box appears.3. Select a system from the System list

Pagina 101 - Using the Host Manager

Logging into a multiple-array environment will display the Summary tab for the Storage Systemsnode (or the Introduction tab if you haven't used P

Pagina 102 - 8 Managing Host Sets

At this point, if you reassign a system to one that runs a non-supported HP 3PAR OS, theAdditional Targets for Multimode will be deselected and disabl

Pagina 103 - Viewing Host Sets

NOTE: When creating additional groups, if you select a server other than the server selectedduring the first instance of group creation, you will crea

Pagina 104 - Viewing Host Set Details

2. In the Common Actions panel, click New Configuration.The New Remote Copy Configuration wizard appears.Targets1. Under Select a Configuration, click

Pagina 105 - The Summary Filter

2. In the Backup group:a. Name - The system(s) NOT selected as the source system, automatically appears. Selecta system.b. Mode - Select Synchronous o

Pagina 106 - The Descriptors Filter

Configuring N-to-1 Remote CopyNOTE: HP 3PAR Remote Copy Software requires an HP 3PAR Remote Copy license. For additionalinformation about the license,

Pagina 107

NOTE: If Fibre Channel ports are not displayed, the ports may not be zoned correctly, or maynot be physically connected. See Configuring Fibre Channel

Pagina 108 - Disk Filter

3. Under the Backup Volume on list:a. Select either Existing or New.b. If you selected Existing, select a backup virtual volume.c. If you selected New

Pagina 109

2. Under Assign a System to Each Target:• Click a storage system graphic. In the menu that appears, select a storage system toassign. Repeat for the o

Pagina 110 - Allocation Settings

c. Syn Period - If you selected Periodic, select second(s), minute(s), hour(s), or day(s) andenter a numeric value for when you wish the source and ba

Pagina 111

6. (Optional) Repeat steps 1 through 5 to add additional virtual volumes to your Remote Copygroup(s).7. Click Next to go to the Summary page, or click

Pagina 112

© Copyright 2012 Hewlett-Packard Development Company, L.P.Confidential computer software. Valid license from HP required for possession, use or copyin

Pagina 113

2 Managing Ports“Configuring Ports” (page 20)“Clearing Port Parameters” (page 24)“Editing a Port Label” (page 24)“Resetting a Port” (page 24)“Setting

Pagina 114

3. Click Next to configure Virtual Volumes or Finish.Virtual Volumes1. In the Source volume on list, select a source virtual volume from the virtual v

Pagina 115

3. Right-click the selection and select Sync Remote Copy Group(s).The Sync Remote Copy Group(s) dialog box appears.4. Click OK.Editing Remote Copy Gro

Pagina 116

4. Click Add.5. If you wish to remove a volume from the group, select a volume from the volume list at thebottom of the wizard and click Remove.6. Cli

Pagina 117

Removing Remote Copy LinksTo remove a Remote Copy link:1. Access the Remote Copy Links screen.2. In the right pane, select the link(s) you wish to rem

Pagina 118 - Viewing the CPGs Tab

• You cannot add new targets to a Synchronous Long Distance Remote Copy configuration.• The following restrictions apply:A 1-to-N Remote Copy configur

Pagina 119 - List Pane

3. For Fibre Channel links, in the Settings groups for each system/port:a. Connection Type - Select Point for point-to-point mode or Loop for arbitrat

Pagina 120 - Displaying Usage Information

3. Under the Backup Volume on list:a. Select either Existing or New.b. If you selected Existing, select a backup virtual volume.c. If you selected New

Pagina 121

The disaster recovery sequence is as follows:1. Failover Remote Copy groups to the backup system.2. Recover the Remote Copy groups to the primary (sou

Pagina 122 - Displaying Alert Information

NOTE: The following procedure assumes that failover has already been performed on onebackup system.To switch failover Remote Copy groups:1. Navigate t

Pagina 123 - Detail Pane

In the right pane of the Remote Copy Groups screen:• Secondary-Rev is displayed under the Source Role column indicating that the groups on thesource s

Pagina 124 - Summary Tab

General1. (Optional) Click the icon to view your settings details in a pane to the right of the screen.The details will update automatically as you en

Pagina 125 - Settings Tab

NOTE: A Remote Copy-ready system means that the system has a Remote Copy license, andhas Remote Copy over Fibre Channel (RCFC) or Remote Copy over IP

Pagina 126 - Virtual Volumes Tab

RC Ports TabThe list pane of the RC Ports tab displays summary information about the system's Remote Copyports. The detail pane displays details

Pagina 127 - Management

RCIP TabThe list pane of the RCIP tab displays summary information about the system's RCIP ports. The detailpane displays details about a selecte

Pagina 128

DescriptionFieldGroupName of device that the port is connected to, e.g.host1, cage0.Connected DevicePort firmware mode setting. Ports in Initiator mod

Pagina 129 - 10 Virtual Volumes

The list pane of the RCFC tab displays summary information about the system's RCFC ports. Thedetail pane displays details about a selected RCFC p

Pagina 130 - Policies and Geometry

DescriptionFieldGroupType of device that the port is connected to. Free, Disk, Host, Peer,or InServ.Connected Device TypeName of device that the port

Pagina 131 - Editing Virtual Volumes

See also:“Manager Pane” (page 396)“Management Tree” (page 395)“Viewing Remote Copy Links” (page 220)“Viewing Remote Copy Targets” (page 221)Viewing Co

Pagina 132 - Configure Virtual Volume

Remote Copy Link Performance ChartThe Remote Copy Link performance chart can be set to graph the thoughput (KBs/Sec) or heartbeat(round trip in ms). T

Pagina 133

Right-clicking the graph displays a menu, which allows you to perform actions such as viewingand setting the chart's properties, copying the char

Pagina 134

“Displaying Tasks” (page 345)“Viewing System Alerts” (page 269)Viewing Remote Copy GroupsA Remote Copy group is a group of virtual volumes on the same

Pagina 135

5. Click Next.The iSNS Settings page appears.iSNS Settings1. (Optional) Enter the Primary IP Address.2. (Optional) Enter the TCP Port number or accept

Pagina 136 - Virtual Volumes

Information about Remote Copy virtual volumes appears on two panes in the Management Window:• All virtual volumes associated with the Remote Copy conf

Pagina 137 - Repairing Virtual Volumes

Information about the Remote Copy links appears on two panes in the Management Window:• The left pane displays a graphical representation of the selec

Pagina 138 - Removing Virtual Volumes

Information about the Remote Copy targets appears on two panes in the Management Window:• The left pane displays a graphical representation of the sel

Pagina 139 - Removing Virtual Volumes 139

Part V Migrating DataThe HP 3PAR Peer Motion feature controls the migration of data from a source system to a destination system.A user can copy the v

Pagina 140 - Tuning Virtual Volumes

15 Using the Peer Motion ManagerThe HP 3PAR Peer Motion Manager is an environment within the HP 3PAR Management Consolethat enables users to perform P

Pagina 141 - Managing Virtual Volume Sets

Creating a Peer Motion ConfigurationTo use the Create PM Configuration wizard, the following conditions are required:• Verify that your storage system

Pagina 142 - Exporting Virtual Volume Sets

Set Up Connections1. Click on a port in the destination system.2. Select Pick a pair for <destination port>, and then select the port you want p

Pagina 143 - Viewing Virtual Volume Sets

3. Select Apply. (This is enabled when the port parameters are modified.)If the paired port is online, a confirmation dialog box will appear, indicati

Pagina 144

Port Configuration and ZoningAfter zoning is complete, click OK, and then click Verify Configuration when your are returned tothe Set Up Connections s

Pagina 145

Copying Storage Settings and ConfigurationsTo use the Copy Storage Settings and Configurations wizard, the following conditions are required:• Super u

Pagina 146

c. Select Use the following IP address.d. IP Address - Enter the iSCSI port's IP address.e. Subnet Mask - Enter the iSCSI port's subnet mask

Pagina 147

Copy Storage Settings and ConfigurationsThis wizard allows you to copy storage settings for:• Domains• Domain sets• Hosts• Host setsThe wizard allows

Pagina 148

Migrating DataTo use the Migrate Data wizard, the following conditions are required:• Super user role• Peer Motion license• Any Peer Motion configurat

Pagina 149 - Exporting Virtual Volumes

2. If you selected Online Migration or Minimally Disruptive Migration, select the Host or HostSet|Linked Hosts for which you wish to migrate virtual v

Pagina 150 - Converting Virtual Volumes

provisioning type to each copy. If your list of volumes contains a mix of Thin and fullyprovisioned volumes, that mix is retained upon import.• Thin –

Pagina 151 - Convert Virtual Volumes

Online Data Confirmation1. Configure the switch to unzone the source system.2. Click Verify.If the system zoning is correct, you will receive a confir

Pagina 152 - 11 Viewing Virtual Volumes

Minimally Disruptive Data Migration Confirmation1. Shut down the host system. (You must use Shut Down, not Restart.)2. Click Verify.3. Click Continue.

Pagina 153

NOTE: You will receive a warning message if either of the following licenses is missing:• Thin provisioning (which is needed to create a thin volume)•

Pagina 154

Removing Peer VolumesTo use the Remove Peer Volumes command, the following conditions are required:• Super user role• A Peer Motion configuration that

Pagina 155

3. Select the Select to also delete check box if you wish to delete any listed volumes not exportedto a host and listed volumes that are part of a vol

Pagina 156

To use the Remove PM Configuration command, the following conditions are required:• Super user role• A Peer Motion configuration that has a source and

Pagina 157

b. Subnet Mask - Enter the RCIP port's subnet mask. The subnet mask is required.c. Gateway - Enter the RCIP port's gateway address.d. MTU li

Pagina 158

4. Click OK. When the migration host exists on the source system, clicking OK also removes themigration host on the source system. (The dialog box tha

Pagina 159

Viewing a Peer Motion ConfigurationTo view the current Peer Motion configuration:1. Select a storage system in the Management Tree.2. Select Peer Moti

Pagina 160

Summary TabThe Summary tab is divided into a left pane and a right pane. The left pane displays the PeerMotion topology in either Overview or Physical

Pagina 161

DescriptionFieldGroup• Incompatible destination system version• Unsupported version of source or destination system• Unknown• NormalDisplays the numbe

Pagina 162 - Advanced Tab

DescriptionFieldGroupIndicates whether a task is Running, Canceled, Failed, orCompleted.StatusThe task progress, if currently running.ProgressThe time

Pagina 163 - SCSI Reservations Tab

DescriptionFieldGroupThe last time the task was run.Last TimeThe first time the task was run.First TimeViewing Port InformationTo view the Ports scree

Pagina 164 - VLUNs Tab

The detail pane contains a Summary tab. If the connected device type is "Host," there will also bea Hosts tab.The Summary Screen Detail Pane

Pagina 165 - Active LUNs Tab

DescriptionFieldGroupMaximum Transmission Unit. The greatest amount of data or "packet" size thatcan be transferred at one time over a parti

Pagina 166 - Path Summary Tab

Clicking the highlighted value under Host Name displays the Host Summary screen or the Systemscreen, depending on the connected device type.Viewing St

Pagina 167 - Layout Tab

The following information is displayed for both Source and Destination systems:DescriptionColumnThe host set name.NameThe domain (if any) the host set

Pagina 168 - Viewing the CPG Space Tab

Initializing a PortNOTE: This operation can only be performed on Fibre Channel (FC) and Remote Copy overFibre Channel (RCFC) ports.To initialize a por

Pagina 169 - 12 Managing VLUNs

The Summary Tab displays the following information for the Source and Destination systems:DescriptionFieldGroupThe number of users on the system.Users

Pagina 170 - Active VLUNs Tab

Security & Domains Node Domains TabThe following information is displayed for both Source and Destination systems:DescriptionColumnThe domains on

Pagina 171

Viewing Migration Data InformationTo view migration data:1. Select Peer Motion in the Manager Pane.2. Select Migrate Data under Peer Motion Configurat

Pagina 172

The list pane provides the following in formation:DescriptionColumnThe name of a host on the source system.NameThe domain (if any) of which the host i

Pagina 173 - Managing AO Configuration

The list pane provides the following information:DescriptionColumnThe name of a host set on the source system.NameThe domain (If any) to which the hos

Pagina 174 - Schedule AO

The list pane displays a 1:1 mapping between the source and destination hosts. (The source systemmust be connected for the source information to be di

Pagina 175 - Viewing an AO Configuration

DescriptionColumnThe total size (in GiB) of the volumes exported from the source system.Source Total Exported SizeThe name of the destination host set

Pagina 176

The screen is divided into a list pane and a detail pane. A blue arrow icon to the left of a volumename in the list pane indicates the I/O endpoint on

Pagina 177 - The Alerts Tab

The list pane displays the following information:DescriptionColumnThe name of the source volumeSource NameThe state of the source volume.Source StateT

Pagina 178 - The Tasks Tab

DescriptionFieldGroupDescription of the virtual volume's state.State DescriptionSelect the device type, Fast Class (FC), Near Line (NL), or Solid

Pagina 179 - Part IV Creating Backup

2. Right-click the Remote Copy port you wish to disable and then click Disable Interface in themenu that appears.The Disable Interface dialog box appe

Pagina 180 - 13 Creating Copies

DescriptionColumnThe port to which the path is connected.PortThe host's World-Wide Name (WWN) or iSCSI name.Host WWN/iSCSI NameThe size of the VL

Pagina 181 - Editing a Virtual Copy

Summary TabThe Summary screen provides the following in formation. Clicking on any highlighted text will takeyou the corresponding screen so that you

Pagina 182 - Removing a Virtual Copy

DescriptionFieldGroupThe number of host sets on the system.Host SetsLists current operating systems in use.Operating SystemsThe total number of paths

Pagina 183 - Creating a Batch Virtual Copy

Alerts TabThe Alerts screen is divided into a list pane and a detail pane. For details about the informationdisplayed in both panes, see “Alerts Tab”

Pagina 184 - Creating Physical Copies

DescriptionColumnPort firmware mode setting: Initiator, Target, Peer, or Suspended. Ports in Initiator modeare connected to drive cages and ports in T

Pagina 185 - Removing a Physical Copy

DescriptionFieldGroupThe address of a local IP router on the same network as the system, used to forwardtraffic to destinations beyond the local netwo

Pagina 186 - Stopping a Physical Copy

Systems” (page 260). For information about Peer Capable, Peer, and Host ports on an availablesystem, see “Ports Screen” (page 263).DescriptionColumnTh

Pagina 187 - Promoting a Physical Copy

Part VI Maintaining the SystemThis part contains information on managing and maintaining the HP 3PAR StoreServ Storage System.“Responding to Alerts” (

Pagina 188 - Configuring Remote Copy

16 Responding to AlertsManaging AlertsOnce you have accessed and viewed the system alerts, either from the “Alert/Task/ConnectionPane” (page 404) or f

Pagina 189 - Configuring Remote Copy 189

The Summary tab displays the following information:DescriptionFieldGroupThe number of new alerts.New AlertsHealthCheck this box to view the number of

Pagina 190

The Summary tab is divided into a list pane and a detail pane. The list pane displays a summaryof all system ports. The detail pane displays detailed

Pagina 191

The list and the detail panes are described in greater detail below:“List Pane” (page 270)“Detail Pane” (page 271)List PaneThe list pane of the Alerts

Pagina 192

Detail PaneThe detail pane of the Alerts tab displays detailed information about an alert selected in the listpane. The detail pane displays the follo

Pagina 193

C:\...\InFormMC\log\InFormMC.log (for Windows)or:informmc/log/informmc.log (for Solaris)An error dialog box similar to the following appears:If you ex

Pagina 194

The list pane displays the following information:DescriptionColumnThe severity of the event.SeverityThe time the event occurred.TimeA description of t

Pagina 195

5. In the Start Time box, enter a date and time (the entered value will display events greater thanor equal to this time).6. (Optional) Click the End

Pagina 196

17 Locating a SystemThis operation helps locate a system by oscillating the node status LEDs amber and green on allnodes of the system. If desired, th

Pagina 197 - Configuring Remote Copy 197

1. In the Manager Pane, click Systems.2. In the Management Tree, click the system you wish to edit.3. In the Common Actions Panel, click Edit System.T

Pagina 198

2. You have the option of selecting the license from a file or pasting the license key into thedialog. To select the license from a file, click the br

Pagina 199 - Creating Remote Copy Groups

18 Viewing System InformationInformation about your system's provisioning and network settings, capacity, current software level,and system alert

Pagina 200 - Syncing Remote Copy Groups

DescriptionColumnThe total amount of space available from Fast Class devices (in GiB).FC TotalThe percentage of used allocated Fast Class device space

Pagina 201 - Editing Remote Copy Groups

DescriptionColumnThe partner port.PartnerThe WWN of the partner port.Partner WWNIndicates if the system is in a failover state.Failover StateDetail Pa

Pagina 202 - Creating Remote Copy Links

Viewing a Single SystemThe Summary tab for a single system displays the following information. Fields that are highlightedon the summary screen are li

Pagina 203 - Managing Remote Copy Targets

DescriptionFieldGroupNOTE: The HP 3PAR Management Console displays the devices currently installed in yoursystem. For example, if you do not have Fast

Pagina 204

The Settings tab displays the following information:DescriptionFieldGroupThe raw space alert threshold (in GiB) for Fast Class devices.FC Raw Space Al

Pagina 205

DescriptionFieldGroupThe status of the system.StatusThe default routing IP address.Default RouteThe NTP server, if any.NTP ServerViewing System Capaci

Pagina 206 - Removing Remote Copy Targets

NOTE: In the normal situation, the capacity displays show you the space that is consumed byprovisioning (e.g. CPGs, Volumes, and underlying LDs) and t

Pagina 207 - Failover Remote Copy Groups

DescriptionFieldNOTE: Subcontents of the Nearline Total display are identical to the Total displayat the top of this table.Total amount of Solid State

Pagina 208 - Recover Remote Copy Groups

DescriptionFieldGroupIndicates which features are enabled by licenses.Enabled FeaturesLicenseThe date the license key was generated.Key Generation Dat

Pagina 209 - Restore Remote Copy Groups

19 Working with Controller Nodes“Locating Controller Nodes” (page 287)“Viewing Controller Nodes” (page 288)“Editing Controller Node Power Supplies” (p

Pagina 210

See also:“Locating a System” (page 275)Viewing Controller NodesThe Controller Nodes screen displays summary information about system controller nodes

Pagina 211 - RC Ports Tab

DescriptionColumnThe current state of the node; either Normal, Degraded, or Failed. See “System andComponent Status Icons” (page 407).StateThe current

Pagina 212 - RCIP Tab

Summary screen displaying RCFC port information:Summary screen displaying iSCSI port information:Viewing System Ports 29

Pagina 213 - RCFC Tab

DescriptionColumnThe number of times the alert has been issued.Repeat CountThe first occurrence of the alert.First TimeViewing Controller Nodes Detail

Pagina 214

DescriptionFieldGroupThe HP 3PAR OS version currently running on the system.HP 3PAR OS VersionThe total number of slots on the node.SlotsThe number of

Pagina 215 - Inventory Tab

The Ports tab provides the following information:DescriptionColumnGroupThe type of interface card, either Ethernet or Fast Class (FC).TypeCardsThe pos

Pagina 216

The Power Supplies tab provides the following information:DescriptionColumnThe node ID.Node IDThe power supply ID.Power Supply IDThe power supply seri

Pagina 217

The Batteries tab provides the following information:DescriptionColumnThe node ID.Node IDThe power supply ID.Power Supply ID**The battery ID.Battery I

Pagina 218 - Alerts Tab

DescriptionColumnThe reason for resetting the unit.Reset ReasonThe date and time since the unit was reset.Up SinceViewing Controller Node Fans Details

Pagina 219 - Viewing Remote Copy Groups

The Adapter Cards tab displays the following information:DescriptionColumnThe position of the card in the node.SlotThe type of card (e.g., FC, SAS).Ty

Pagina 220 - Viewing Remote Copy Links

DescriptionColumnThe serial number of the drive.Serial NumberLED indicating when the node battery can be replaced.Service LEDThe type of drive (e.g.,

Pagina 221 - Viewing Remote Copy Targets

5. Enter a new alphanumeric serial number in the Serial Number field using numeric characters0 to 9 and alphabetic characters A to F.6. Click OK.Editi

Pagina 222

20 Managing Drive Cages“Viewing Drive Cages” (page 299)“Editing Drive Cages” (page 313)“Locating Drive Cages” (page 313)“Editing Drive Cage Power Supp

Pagina 223 - Part V Migrating Data

ContentsI Connecting to the System...171 Connecting to Systems...

Pagina 224

Summary screen displaying RCIP port information:Summary screen displaying SAS port information:30 Managing Ports

Pagina 225 - Select Systems

DescriptionColumnThe number of disks in the drive cage. The bottom of the Disks column displaysa total disk count.DisksThe total Fast Class capacity i

Pagina 226 - Set Up Connections

DescriptionColumnController node initiator port connected to drive cage port A2.A2 Port (for DC3 drive cages)Controller node initiator port connected

Pagina 227 - Show Port WWNs

DescriptionColumnThe amount of free SSD space in GiB. The bottom of the SSD Free column displaystotal free SSD capacity for all cages.SSD FreeThe amou

Pagina 228 - Port Configuration and Zoning

Viewing Drive Cage SFPsTo view the Drive Cage SFP information:1. Access the Drive Cages screen.2. In the list pane, click the SFPs tab.The list pane o

Pagina 229

The following information appears in the detail pane:DescriptionFieldGroupThe position in the drive cage.CageGeneralInterface card number, as assigned

Pagina 230

The information displayed in the Alerts tab is identical to the information displayed in the SystemsAlerts screen, except the Drive Cage Alerts tab do

Pagina 231 - Migrating Data

The following information is provided:DescriptionFieldGroupThe drive cage name.NameGeneralThe drive cage ID number.IDThe drive cage model.ModelThe dri

Pagina 232 - Import Volumes

DescriptionFieldGroupThe throughput in KB/sec for the Loop B port.Loop BRevision of firmware running on the FC-AL for port A.Loop AConnectivityControl

Pagina 233 - Migrating Data 233

The following information for DC2 and DC4 drive cages is provided:DescriptionColumnThe interface card name.NameFour ports for each FC-AL. For FC-AL A,

Pagina 234 - Online Data Confirmation

The following information for DC1 drive cages is provided:DescriptionColumnThe interface card name.NamePorts for each FC-AL. For FC-AL A, that is A0 a

Pagina 235 - Importing Volumes

The Summary tab provides the following information:DescriptionFieldGroupPort location in Node:Slot:Port format.PositionGeneralThe designated port labe

Pagina 236 - Select Peer Volumes

The following information is displayed:DescriptionColumnPosition of the drive magazine within the drive cage.PositionThe current stage of the drive ca

Pagina 237 - Removing Peer Volumes

The following information is provided:DescriptionColumnPhysical disk ID, as assigned by the system. For unadmitted disks, this columns is blank(--).ID

Pagina 238 - Post Migration Cleanup

The following information is provided for non-SAS drive cages:DescriptionColumnThe drive cage to which the power supply belongs.CageNumeric ID of the

Pagina 239

DescriptionColumnThe last occurrence of the alert.Last TimeA brief description of the alert.MessageThe number of times the alert has been issued.Repea

Pagina 240

3. In the Power Supplies tab displayed in Management Window, right-click the drive cage powersupply you wish to edit and click Edit.4. Enter the drive

Pagina 241

21 Managing Physical DisksThe Systems Manager allows you perform various tasks related to physical disks. Refer to thefollowing sections for more info

Pagina 242

“Viewing the Physical Disks Alerts Tab” (page 325)Viewing the Physical Disks Summary TabTo view the physical disks Summary tab:1. Access the Physical

Pagina 243

DescriptionFieldGroupAmount of storage (in percent) consumed by the disk drive.Allocated PercentageSelect the device type, Fast Class (FC), Near Line

Pagina 244

DescriptionColumnLocation of the disk in the format in Cage:Magazine:Disk format.PositionIndicates whether a physical disk is a Fast Class (FC), Nearl

Pagina 245 - Viewing Port Information

The following information is displayed:DescriptionColumnPhysical disk ID, as assigned by the system. Physical disks are numberedcontiguously during sy

Pagina 246

DescriptionFieldGroupData transfer rate setting (for example, 1 Gbps). Auto indicates that thesystem automatically selects the rate.Configured RateMax

Pagina 247 - The Hosts Screen Detail Pane

DescriptionColumnLocation of the disk in (Cage:Magazine:Disk format.PositionIndicates whether a physical disk is a Fibre Channel (FC), Nearline (NL),

Pagina 248 - Hosts Node

The following information is displayed:DescriptionColumnPhysical disk ID, as assigned by the system. Physical disks are numberedcontiguously during sy

Pagina 249 - Security & Domains Node

The following information is displayed:DescriptionColumnPhysical disk ID, as assigned by the system. Physical disks are numberedcontiguously during sy

Pagina 250

The following information is displayed:DescriptionColumnPhysical disk ID, as assigned by the system. Physical disks are numbered contiguouslyduring sy

Pagina 251

The following information is displayed:DescriptionColumnPhysical disk ID, as assigned by the system. Physical disks are numbered contiguouslyduring sy

Pagina 252

The following information is displayed:DescriptionColumnPhysical disk ID, as assigned by the system. Physical disks are numbered contiguouslyduring sy

Pagina 253

22 Managing FansThe Systems Manger allows you to view system fan information for physical disks. For moreinformation see “Viewing System Fans” (page 3

Pagina 254

*Indicates the column is for V-Class systems only.**Indicates the column is for E-Class systems only.Viewing System Fans 327

Pagina 255

23 Managing ProvisioningThe Provisioning Manager allows you to perform all provisioning tasks for your HP 3PAR StoreServStorage System. These tasks in

Pagina 256

The Summary tab displays the general provisioning of all connected systems. The followinginformation is included:DescriptionColumnThe system name.Syst

Pagina 257

DescriptionFieldGroup(For RCFC ports.) The current state of the link.Link StatePrimary Internet Storage Name Service (iSNS) server IP address. iSNSpro

Pagina 258 - Summary Screen

The following information is displayed:DescriptionFieldGroupThe total number of CPGs.CPGsGeneralThe total number of virtual volumes.Virtual VolumesThe

Pagina 259 - Active VLUNs Screen

DescriptionFieldGroupof the selected device type is displayed in graphical form.You can also select All to display capacity and capacityusage for all

Pagina 260 - Hosts Screen

List PaneThe list pane provides the following information:DescriptionColumnThe task ID.IDThe task type.TypeThe virtual volume name on which the task w

Pagina 261

24 Managing Data AllocationThe Layout Grid Manager allows you to view layout grids showing patterns of virtual volume,Common Provisioning Group (CPG),

Pagina 262

The following information is displayed:DescriptionColumnThe name of the system.SystemThe model number of the system.ModelThe number of physical disks

Pagina 263 - Ports Screen

4. In the Management Window, select the Virtual Volume you wish to view. You may also selectmultiple volumes. The usage blocks will be a different col

Pagina 264

4. In the Management Window, select the CPG you wish to view. You may also select multipleCPGs to view. The usage blocks will be a different color for

Pagina 265

Viewing the Logical Disk Layout ScreenThe logical disks layout screen allows you to see how chunklets are used by the logical disks inthe system. The

Pagina 266

25 Tracking PerformanceThe Performance & Reports Manager allows you to:• Create charts from predefined performance charts for physical disks, host

Pagina 267

Each started chart is tabbed at the top of the Management window. Simply click the tab for thechart you wish to view.At any time, you can use the cont

Pagina 268 - 16 Responding to Alerts

The following information is provided:DescriptionFieldGroupThe location of the SFP within the system.PositionGeneralCurrent condition of the SFP.State

Pagina 269 - Viewing System Alerts

Creating a New ChartTo create a new performance chart, access the Chart Configuration wizard:1. In the Manager Pane, click Performance & Reports.2

Pagina 270

4. If you selected individual objects:a. (Optional) If you do not want a plot that combines all selected objects, uncheck the Createa plot that aggreg

Pagina 271 - Removing System Alerts

4. If you selected individual objects:a. (Optional) If you do not want a plot that combines all selected objects, uncheck the Createa plot that aggreg

Pagina 272 - Managing Events

b. Click the icon and select a date.c. To change the date or time now displayed, click on any portion of the date or time, thenclick the up or down ar

Pagina 273 - Filtering Events

26 Tracking and Scheduling TasksThe Task & Schedules Manager allows you to retrieve, remove, cancel, and schedule tasks on HP3PAR StoreServ Storag

Pagina 274 - 7. Click Get Events

Displaying TasksYou can display completed, running, failed, and canceled tasks within a specified time period.To display tasks:1. In the Manager Pane,

Pagina 275 - 17 Locating a System

3. Right-click the selection and then click Cancel Task in the menu that appears.The Cancel Task(s) dialog box appears.4. Click OK.Viewing the Schedul

Pagina 276 - Setting the License

The list pane provides the following information:DescriptionColumnThe name of the system on which the task is scheduled (Storage Systemsnode only.)Sys

Pagina 277 - Setting the License 277

• Tasks & Schedules ManagerCommon Actions Panel – Contains options for creating a schedule to create a virtualcopy, create a consistency group vir

Pagina 278 - 18 Viewing System Information

Scheduling TasksThe following scheduling actions are available:“Schedule Create Virtual Copy” (page 352)“Schedule Create Consistency Group Virtual Cop

Pagina 279

DescriptionFieldGroupThe manufacturer's recommended lower-limit alarm level.Low Alarm ThresholdThe manufacturer's recommended upper-limit al

Pagina 280 - Viewing a Single System

This recurrence option allows you to specify:◦ How often to repeat within an hour range. By default, the task recurs during workinghours of 9AM-5PM. T

Pagina 281 - Viewing System Settings

This recurrence option allows you to specify:◦ Minutes – (Required) The Minutes checkbox is selected and disabled. By default, noneof the minutes is s

Pagina 282

– If day 31 is selected, the checkboxes for February, April, June, September, andNovember are disabled.– If day 29, 30, or 31 is selected, the checkbo

Pagina 283 - Viewing System Capacity

14. Click OK.Edit Volume Set Name DialogWhen editing the volume set name, you can compose the name by appending your own text orpredefined tokens to t

Pagina 284

SummaryReview your settings, then click Finish to complete the wizard.Schedule Compact CPGThe Schedule Compact CPG wizard is similar to the Compact CP

Pagina 285 - Viewing System Software

performance of the tiered CPGs is important; for example, 3 hours at the end of each businessday11. Enter the time to End analyzing the tiered CPGs. T

Pagina 286 - DescriptionFieldGroup

4. The schedule will automatically resume.Remove a ScheduleTo remove a schedule:1. Selection Tasks & Schedules in the Manager Pane.2. Select the S

Pagina 287 - Locating Controller Nodes

27 Creating TemplatesThe HP 3PAR Management Console allows you to create templates that enable you to apply a setof parameters again and again to crea

Pagina 288 - Viewing Controller Nodes

Creating Similar TemplatesYou can create new Common Provisioning Group (CPG) and Virtual Volume templates based onexisting templates. To do this:1. Ac

Pagina 289

The Templates screen is divided into a list pane and a detail pane. The “List Pane” (page 359)displays summary information about the system's tem

Pagina 290

2. In the Management Window, click the CNA tab.The CNA tab is divided into a list pane and a detail pane. The list pane displays a summary of allCNA p

Pagina 291 - 3. Select a node

28 Tuning the SystemWhether new nodes are added or there are cage, magazine, or disk upgrades, the Tune Systemfeature allows you optimize system perfo

Pagina 292

• Max Chunklets Moved Simultaneously – The maximum number of chunklets to be moved fromone physical disk to another during the reallocation operation.

Pagina 293

To change the allocation settings:1. Enter a value for the Volume Allocation Imbalance Threshold percentage.2. Enter a value for the Chunklet Allocati

Pagina 294

5. Select the Analyze only checkbox if you want to view an analysis instead of running the tuningtask.6. When you are ready to run the task (or see th

Pagina 295

To change the allocation settings:1. Enter a value for the Volume Allocation Imbalance Threshold percentage.2. Enter a value for the Chunklet Allocati

Pagina 296

The results will appear in the Task Details pane of the Task tab under Tasks & Schedules. For detailsabout the Task tab, see “Tasks Tab” (page 331

Pagina 297

6. Select at least one CPG. (For information on selecting more than one item, refer to “SelectingMultiple Items” (page 406).7. Enter a value for the M

Pagina 298

To tune only physical disk chunklets:1. Select Provisioning in the Manager Pane.2. Click Tune System in the Common Actions panel.The Tune System wizar

Pagina 299 - 20 Managing Drive Cages

Part VII Taking Inventory of the Storage System HardwareThis part contains information on using the Hardware Inventory Manager to gather data related

Pagina 300

29 Using the Hardware Inventory ManagerThe Hardware Inventory Manager provides information about all hardware used in the connectedHP 3PAR StoreServ S

Pagina 301 - Viewing Drive Cage Capacity

Summary, Sessions, and Host tabs are displayed for iSCSI-configured ports. The information onthese tabs is identical to that displayed on correspondin

Pagina 302

30 Viewing the Hardware Inventory Summary TabThe Hardware Inventory Summary tab provides quick summary information about hardware usedin all connected

Pagina 303 - Viewing Drive Cage SFPs

DescriptionColumnContact information for the system owner (if entered during system setup).ContactAny notes about the system (if entered during system

Pagina 304 - Viewing Drive Cage Alerts

31 Viewing the Node Subsystems TabThe Hardware Inventory Node Subsystems tab provides information about controller nodecomponents. The information is

Pagina 305 - Viewing Drive Cage Details

DescriptionColumnThe manufacturer of the controller node.ManufacturerThe controller node serial number.Serial Number*The part number of the controller

Pagina 306

*Not displayed when viewing information for an individual system.Viewing the Node Subsystems Internal Drives TabThe Node Subsystems Internal Dives tab

Pagina 307

The Node Subsystems Physical Memory tab displays the following information:DescriptionColumnThe system on which the adapter resides.System*The DIMM na

Pagina 308

The Node Subsystems Adapter Cards tab displays the following information:DescriptionColumnThe system on which the adapter resides.System*The adapters

Pagina 309

The Node Subsystems SFPs tab displays the following information:DescriptionColumnThe name of the system.System*The SFP's name, shown in node:slot

Pagina 310

The Node Subsystems Power Supplies tab displays the following information:DescriptionColumnThe system on which the power supply resides.System*The pow

Pagina 311

DescriptionColumnThe model name, if applicable.Model Name*The battery's expiration date.Expiration Time**The position of the node in the node cha

Pagina 312

DescriptionColumnName of device that the port is connected to, e.g. host1, cage0.Connected DeviceIndicates whether port mode change from initiator to

Pagina 313 - Locating Drive Cages

32 Viewing the Cage Subsystems TabThe Hardware Inventory Cage Subsystems tab provides information about system drive cagecomponents. The information i

Pagina 314 - 5. Click OK

DescriptionColumnThe model name, if applicable.Model Name*The drive cage firmware version.Firmware VersionThe type of drive cage (DC2, DC3, DC4, DCS1,

Pagina 315 - 21 Managing Physical Disks

Viewing the Cage Subsystems SFPs TabThe Cage Subsystems SFPs tab displays information about the system's SFPs.To access the Cage Subsystems SFPs

Pagina 316 - 2. Click the Summary tab

The Cage Subsystems Magazines tab displays the following information:DescriptionColumnThe name of the system.System*The drive magazine name, in node:s

Pagina 317

The Cage Subsystems Physical Disks tab displays the following information:DescriptionColumnThe system name.System*The disk name in Cage:Magazine:Disk

Pagina 318

DescriptionColumnThe manufacturer of the power supply.ManufacturerThe power supply's serial number.Serial Number*The part number of the power sup

Pagina 319

33 Viewing the All TabThe Hardware Inventory All tab provides an overview of all hardware components used in allconnected HP 3PAR StoreServ Storage Sy

Pagina 320

34 Support and Other ResourcesContacting HPFor worldwide technical support information, see the HP support website:http://www.hp.com/supportBefore con

Pagina 321

See:For information about:HP 3PAR Secure Service Custodian Configuration UtilityReferenceConfiguring the Secure Service Custodian server in order tomo

Pagina 322 - Displaying State Information

See:For information about:Planning for HP 3PAR storage system setupHardware specifications, installation considerations, power requirements, networkin

Pagina 323 - Displaying Paths Information

The following information is provided:DescriptionFieldGroupThe port location in Node:Slot:Port format.PositionGeneralThe designated port label.LabelPo

Pagina 324

Typographic conventionsTable 1 Document conventionsElementConventionBold text• Keys that you press• Text you typed into a GUI element, such as a text

Pagina 325

35 Documentation feedbackHP is committed to providing documentation that meets your needs. To help us improve thedocumentation, send any errors, sugge

Pagina 326 - 22 Managing Fans

Part VIII AppendicesThis part contains additional information related to the HP 3PAR Storage System.“Interface Components” (page 393)“Interface Tools”

Pagina 327 - Viewing System Fans 327

A Interface Components“Components of the Interface” (page 393)“Interface Tools” (page 405)Components of the InterfaceThe HP 3PAR Management Console is

Pagina 328 - 23 Managing Provisioning

DescriptionCommandMenuExpands the Application window so it consumes the entire HP 3PARManagement Console window.MaximizeDisplays the Export Data windo

Pagina 329

DescriptionCommandDisplays the Connect dialog box, allowing you to connect additional storage server(s).ConnectRefreshes the HP 3PAR Management Consol

Pagina 330

Common Actions PanelThe Common Actions panel provides quick access to functions commonly performed with eachmanager in the Manager Pane. Clicking an a

Pagina 331

The following managers are contained in the Manager Pane:“System Manager” (page 397)“Host Manager” (page 398)“Provisioning Manager” (page 399)“Layout

Pagina 332

Host ManagerThe Host Manager allows you to view and perform host-specific actions and information. Whenthe Host Manager is selected, the Management Tr

Pagina 333 - 24 Managing Data Allocation

Provisioning ManagerThe Provisioning Manager allows you to view and perform system provisioning actions andinformation. When the Provisioning Manager

Pagina 334

SFP...44Viewing System iSCSI Por

Pagina 335 - Viewing the CPG Layout Screen

DescriptionFieldGroupIndicates whether port mode change from initiator to targetor vice versa is Allowed or Prohibited. This setting isconfigured usin

Pagina 336

Remote Copy ManagerThe Remote Copy Manager allows you to view and perform Remote Copy actions and information.When the Remote Copy Manager is selected

Pagina 337

Performance & Reports ManagerThe Performance & Reports Manager allows you to view system performance information and workwith performance char

Pagina 338 - 25 Tracking Performance

Events & Alerts ManagerThe Events & Alerts Manager allows you to view system alerts and events. When the Event Manageris selected, the Managem

Pagina 339 - Viewing Performance 339

Security & Domains ManagerThe Security & Domains Manager allows you to view and work with system users, domains, andconnections. When the Secu

Pagina 340 - Creating a New Chart

Management WindowThe Management Window displays data, as well as additional options for viewing data. The datadisplayed in the Management Window is de

Pagina 341 - Editing a Chart

B Interface ToolsNavigating the Management Console InterfaceThis chapter outlines how to use the HP 3PAR Management Console and provides an overview o

Pagina 342 - Creating a Report

4. Click Apply.5. Click OK to exit the Preferences dialog box.Selecting Multiple ItemsThe HP 3PAR Management Console supports the standard Shift+click

Pagina 343 - Creating a Report 343

The following icons are used:DescriptionNameIconThe status bar displays only the highestseverity level found on connectedsystems.Alert SeveritySee “Al

Pagina 344 - Viewing the Tasks Tab

Expand the management tree for an individual system to see details about the various states.408 Interface Tools

Pagina 345 - Cancelling Tasks

Refreshing the HP 3PAR Management ConsoleTo refresh the data displayed in the Management window and Alert/Task/Connection panel, clickRefresh in the M

Pagina 346 - Viewing the Schedules Tab

The following information is provided:DescriptionFieldGroupThe location of the SFP within the system.PositionGeneralCurrent condition of the SFP.State

Pagina 347

1. Access the Export Data dialog.2. From the Select a format list, select either CSV Format or HTML Format.3. From the Destination group box, select e

Pagina 348

Using the Complex FilterThe complex filter allows you to define specific criteria by which to search.Access the complex filter by clicking Filter on t

Pagina 349 - The Common Schedule Panel

To ungroup a criteria group defined in the Criteria field, select the grouped criteria and clickUngroup.Negating CriteriaTo negate criteria defined in

Pagina 350

3. Click Apply to continue modifying preferences, or click OK when finished.Resetting Per-Table Format Settings to Default SettingsTo set reset per-ta

Pagina 351 - Viewing the Schedules Tab 351

NOTE: See “Setting Global Preferences” (page 412) to learn how to make global changes totables and HP 3PAR Management Console display properties using

Pagina 352 - Schedule Create Virtual Copy

The following figure displays the Manager Pane minimized:Resizing the Manager PaneTo resize the Manager Pane:1. Place your mouse on the top edge of th

Pagina 353 - Configure Virtual Copies

The last Manager button in the Manager Pane is minimized and is displayed as an icon at thebottom of the Manager Pane.Repeating steps 1 and 2 continue

Pagina 354 - Schedule Compact CPG

The most recently minimized Manager button is restored to the Manager Pane (the left-most displayedManager icon).Repeating steps 1 and 2 continues to

Pagina 355 - Resume a Schedule

NOTE: When adding a Manager button back to the Manager Pane, you must manually resizethe Manager Pane in order for all Manager buttons to display. See

Pagina 356 - Remove a Schedule

Glossaryactive VLUN The connection of a virtual volume and a LUN for a particular host on a particular port. An activeVLUN is created when a VLUN temp

Pagina 357 - 27 Creating Templates

1. Access the Ports screen.2. In the Management Window, click the RCFC tab.The RCFC tab is divided into a list pane and a detail pane. The list pane d

Pagina 358 - Viewing Templates

data cache The dual in-line memory modules (DIMMs) that support the 3PAR ASIC located in a controllernode.data space See snapshot data space.DC2 drive

Pagina 359

iSCSI adaptor An iSCSI PCI host bus adapter (HBA) located in a controller node. The iSCSI adapter connectsa controller node to a host.iSCSI name A val

Pagina 360 - 28 Tuning the System

port-presentsVLUN templateA VLUN template that allows any host connected to a particular port to see a virtual volume asa specified LUN. See also VLUN

Pagina 361 - Tune System 361

snapshotadministrationspaceThe space on a virtual volume that is used to track changes to the data since a snapshot of avirtual volume was created.sna

Pagina 362 - 362 Tuning the System

VLUN template Sets up an association between a virtual volume and a LUN-host, LUN-port, or LUN-host-portcombination by establishing the export rule, o

Pagina 363 - Tuning 3.1.1 Systems

“RCFC Port Summary” (page 43)“SFP” (page 44)RCFC Port SummaryThe RCFC port summary is displayed on the Summary tab.The following information is provid

Pagina 364 - 364 Tuning the System

DescriptionFieldGroupWorld Wide Name of the remote port.Remote Port WWNWorld Wide Name of the remote node.Remote Node WWNIndicates whether port mode c

Pagina 365 - Tune CPGs

DescriptionFieldGroupThe manufacturer's recommended lower-limit warning level.Low Threshold WarningThe manufacturer's recommended upper-limi

Pagina 366 - 366 Tuning the System

DescriptionColumnMaximum Transmission Unit. The greatest amount of data or "packet" size that canbe transferred at one time over a particula

Pagina 367

DescriptionFieldGroupMaximum Transmission Unit. The greatest amount of data or"packet" size that can be transferred at one time over a parti

Pagina 368

The RCIP tab is divided into a list pane and a detail pane. The list pane displays a summary of allRCIP ports in the system. The detail pane displays

Pagina 369

DescriptionFieldGroupName of device that the port is connected to, e.g. host1, cage0.Connected DevicePort firmware mode setting. Ports in Initiator mo

Pagina 370

General...69Domains...

Pagina 371 - DescriptionColumn

The SAS screen can be filtered by Summary and Settings information.“Summary Information” (page 50)“Settings Information” (page 52)Summary InformationT

Pagina 372 - The controller node name.Name

The detail pane provides a “Summary Tab” (page 51), and if the connected device type is disk,it will also display a “Physical Disks Tab” (page 51).Sum

Pagina 373 - Tab” (page 372)

DescriptionColumnThe number of errors on the connected disk.I/O Error CountThe state of the disk. See “System and Component Status Icons” (page 407).S

Pagina 374

The list pane provides the following information:DescriptionColumnThe severity of the alert. See “Alert Severity Indicators” (page 406).SeverityThe al

Pagina 375

Part II Managing SecurityThis part contains information on managing security for domains and users though the Security Manger.“Managing Users with Sec

Pagina 376

3 Managing Users with Security ManagerThe Security Manager provides the functionality to view and work with HP 3PAR StoreServ StorageSystem users.“Cre

Pagina 377

2. In the Management Tree, select the system with the user(s) you wish to view, then select theUsers node.The Users summary screen is displayed in the

Pagina 378

2. Enter the current password, new password, and then confirm the new password.NOTE: The password must be between six and eight characters.3. Click Ne

Pagina 379

The Connections screen provides the following information:DescriptionColumnThe system ID.Connection IDThe user name.User NameThe system name.SystemThe

Pagina 380

4 Managing Domains with Security ManagerThe Security Manager provides functionality to view and work with domains and domain sets, aswell as objects b

Pagina 381

Detail Pane...98VLUN Templates Tab...

Pagina 382

Viewing DomainsYou can view information about domains for all connected HP 3PAR StoreServ Storage Systemsor a single system.Viewing Domains for All St

Pagina 383

Viewing the Domains Summary TabAfter accessing the Domains screen, the Summary tab is displayed by default. The DomainsSummary tab displays all object

Pagina 384

DescriptionFieldGroupThe number of fully provisioned virtual volumes associated with thedomains in the system.Fully ProvisionedThe total number of vir

Pagina 385

The list pane displays the following information:DescriptionColumnThe domain name.DomainThe name of the system with which the domain is associated.Sys

Pagina 386 - 33 Viewing the All Tab

DescriptionFieldGroupThe date and time the domain was created.Creation TimeThe maximum time a volume will be retained in the domain.Maximum Volume Ret

Pagina 387 - HP 3PAR documentation

Editing DomainsTo edit an existing domain, access the Edit Domain wizard:1. Click Security & Domains in the Manager Pane.2. From the Management Tr

Pagina 388

2. Click Create Domain Set in the Common Actions Panel.The Create Domain Set wizard appears.General1. Select a system on which the domain set will be

Pagina 389

DescriptionColumnThe number of hosts connected to the domain set.HostsThe size (in GiB) of the domain set.Total Exported SizeAny user entered notes wh

Pagina 390 - HP 3PAR branding information

Viewing Summary InformationThe Summary filter provides the following information:DescriptionColumnThe name of each domain within the domain set.Domain

Pagina 391 - 35 Documentation feedback

DescriptionColumnThe size (in GiB) of user CPGs.CPG User SizeThe size (in GiB) of used user CPGs.CPG User Use SizeThe size (in GiB) of admin CPGs.CPG

Pagina 392 - Part VIII Appendices

Disk Filter...117Summary...

Pagina 393 - A Interface Components

NOTE: If you wish to remove multiple domain sets (see “Selecting Multiple Items” (page 406)),select the domain sets you wish to remove before right-cl

Pagina 394 - Main Toolbar

5 Managing LDAP with Security ManagerThe HP 3PAR Management Console supports the following types of LDAP authentication:• SimpleSimple binding◦◦ Simpl

Pagina 395 - Management Tree

7. For Simple binding:a. Select a value in the Start-TLS list:no – The LDAP server does not use TLS protocol to create an encrypted connection (defaul

Pagina 396 - Manager Pane

8. For SASL binding:a. Select an SASL Mechanism: PLAIN, DIGEST MD5, or GSSAPI.b. Enter the Accounts DN (the Distinguished Name for accounts).c. Enter

Pagina 397 - System Manager

Enter Certificate1. Select Certificate File then click the Browse button to load a local certificate, or select Certificateif you wish to paste the co

Pagina 398 - Host Manager

The LDAP Summary ScreenThe Summary screen provides different information depending on the type of LDAP configuration.When no LDAP configuration exists

Pagina 399 - Layout Grid Manager

DescriptionFieldGroupvalue of the Domain Name Attribute is used to look up anattribute in the group that holds the name of a domain. If thedomain is t

Pagina 400 - Peer Motion Manager

For an LDAP configuration with SASL binding, the following in formation is provided:DescriptionFieldGroupThe IP address of the LDAP server.LDAP Server

Pagina 401

DescriptionFieldGroupIndicates the type of binding: Simple or SASL.BindingAuthenticationParametersIndicates whether binding with SSL is used.Use SSLIn

Pagina 402 - Tasks & Schedules Manager

Testing an LDAP ConnectionTo test an LDAP connection:1. In the Management Tree, select the LDAP node under the system containing the LDAPconfiguration

Pagina 404 - Status Bar

Removing AuthorizationsTo remove an authorization:1. Click Security & Domains in the Management Pane.2. Select the LDAP node under the system cont

Pagina 405 - B Interface Tools

6 The Security ManagerThe Security Manager allows you to create and manage users and domains, as well as view users,domains, and connections on the HP

Pagina 406 - Understanding Icons

The Security System summary screen provides the following information:DescriptionFieldGroupThe total number of system users. The Users heading is a li

Pagina 407 - Accordion Control

Part III Creating StorageThis part contains information on managing domains, hosts, provisioning, virtual volumes, and VLUNs.“Managing Hosts” (page 84

Pagina 408 - 408 Interface Tools

7 Managing HostsThe Host Manager allows the following operations:“Creating Hosts” (page 84)“Editing Hosts” (page 85)“Removing Hosts” (page 87)“Viewing

Pagina 409 - Exporting Data

Fibre Channel1. To assign available WWNs:a. Select one or more WWNs from the Available WWNs list. This list displays WWNs forall physically connected

Pagina 410 - Filtering

Host Settings1. In the General group box:a. Name - Enter a new host name.b. Host OS - Select the operating system running on the host.c. Persona - The

Pagina 411 - Removing Criteria

3. Click Next to view summary information, or click Finish to close the wizard and edit the hostwith the information gathered.SummaryReview the summar

Pagina 412 - Setting Preferences

The following information is provided:DescriptionFieldGroupThe total number of hosts.HostsGeneralThe total number of host sets.Host SetsProvides a bre

Pagina 413 - Column Ordering

The following information is provided:DescriptionFieldGroupThe total number of hosts. This is also a link to the Host screen.HostsGeneralThe total num

Pagina 414 - Table View

12 Managing VLUNs...169Exporting VLUNs...

Pagina 415 - Showing Fewer Manager Buttons

Viewing Host InformationTo view more in-depth information about hosts for a single system, perform the following:1. In the Manager pane, click Hosts.2

Pagina 416 - Showing More Manager Buttons

The following descriptor information is provided:DescriptionColumnThe host name.NameThe domain in which the host resides.DomainThe location of the hos

Pagina 417 - Setting Preferences 417

DescriptionColumnThe multipathing software in use on the host.MultipathThe version of the multipathing software.Multipath VersionThe host clustering s

Pagina 418 - Restoring Defaults

The following information is displayed:DescriptionFieldGroupThe host name.NameGeneralThe host ID.IDThe domain in which the host resides.DomainThe numb

Pagina 419 - Glossary

The following information is provided:DescriptionFieldGroupThe host name.Host NameGeneralThe host ID.IDThe domain in which the host resides.DomainThe

Pagina 420 - 420 Glossary

VLUN TemplatesThe following information is provided:DescriptionColumnThe exported LUN value. Each LUN is a link to the VLUN template.LUNThe domain in

Pagina 421

DescriptionColumnThe name of the host to which the VLUN is exported.HostThe port to which the path is connected, in Node:Slot:Port format.PortThe host

Pagina 422 - 422 Glossary

The following information is provided:DescriptionColumnThe volume name. Volume tree depth in parenthesis. Each name is a link to thevirtual volume tab

Pagina 423

DescriptionColumnPrimitive sequence protocol error. There were errors during the transmission of afibre channel primitive sequence. This might indicat

Pagina 424 - 424 Glossary

VLUN Templates TabThe following information is provided on the VLUN Templates tab:DescriptionColumnThe exported LUN value.LUNThe domain in which the V

Commenti su questo manuale

Nessun commento