For the minimum firmware versions supported, see Table 3-1.
Upgrade the firmware versions, if necessary. You can download firmware from the HP IT
Resource Center on the HP website at:
http://www.itrc.hp.com
Table 3-1 Minimum Firmware Versions
Minimum Firmware VersionComponent
I.10.43, 08/15/2007HP J4903A ProCurve Switch 2824
J00P19Code Version
MSA2000fc Storage Controller F300R21Memory Controller
15.010Loader Version
W420R35Code Version
MSA2000fc Management Controller
12.013Loader Version
2042Code VersionMSA2000fc Enclosure Controller
LCA 55Hardware Version
MSA2000fc RAID Controller
Hardware
27CPLD Version
26Host Interface Version
2.6.14Kernel
SAN Switch v5.3.0Fabric OS
4.6.4BootProm
P56 1/24/2008BIOS
DL380 G5 Server
1.60 7/11/2008iLO
v2.5.0IB ConnectX NIC MT 25418
Mezzanine Card (448262-B21)
v1.0.54X DDR IB Switch Module for HP
c-Class BladeSystem (410398-B21)
v5.1.0-870 6/12/2008Software
IB Switch ISR 9024 D-M DDR
v1.0.0.6Firmware
3.2 Installation Requirements
A set of HP SFS G3.0-0 file system server nodes should be installed and connected by HP in
accordance with the HP SFS G3.0-0 hardware configuration requirements.
The file system server nodes use the Red Hat Enterprise Linux 5 Update 2 (RHEL5U2) Software
as a base. The installation process is driven by the Red Hat Kickstart process, which is used to
ensure that required RPMs from RHEL5U2 are installed on the system.
3.2.1 Kickstart Template Editing
A Kickstart template file called sfsg3DVD.cfg is supplied with HP SFS G3.0-0. This file can be
found in the top-level directory of the HP SFS G3.0-0 DVD, and is also present on an installed
system in /opt/hp/sfs/scripts/sfsg3DVD.cfg. The sfsg3DVD.cfg file must be copied
from the DVD, edited, and made available during installation.
This file must be modified by the installer to do the following:
• Set up the time zone.
• Specify the system installation disk device and other disks to be ignored.
20 Installing and Configuring HP SFS Software on Server Nodes