# forostmsas create vdisk level raid6 disks 16-26 spare \
27 vdisk2 ; done
NOTE: For MGS and MDS nodes, HP SFS uses RAID10. An example MSA2000 CLI
command to do this is:
# formdsmsas create vdisk level raid10 disks 0-4:5-89 spare 10,11
vdisk1
# forallmsas show vdisks ; done
Make a note of the size of the vdisks and use that number in the following step.
5. Create a volume to fill each vdisk. For example:
# forostmsas create volume vdisk vdisk1 size size \
mapping 0-1.5 volume1 ; done
# forostmsas create volume vdisk vdisk2 size size \
mapping 0-1.6 volume2 ; done
# formdsmsas create volume vdisk vdisk1 size size \
mapping 0-1.4 volume1 ; done
# forallmsas show volumes ; done
6. Reboot the file system servers to discover the newly created volumes.
2.3 Using the CLI to Configure Multiple MSA2000 Arrays 17