2. Go to the storage fabric and create the zone. In this example, a switch which exists in “san3”
above is connected. The zone should have the same name as the storage pool entry, as is
shown by the highlighted entry.
3. Go to the disk array management interface (in this case CommandView managing an EVA)
and create a host entry and present the LUN. In the first figure, the host entry that is created
on the EVA uses the same name as the storage pool entry. The host entry is assigned the
initiator WWN identified in the storage pool entry:
4. Create the vdisk on the EVA and present it to the host above:
Corrective procedures 107