ContentsHP E1351A/53A FET Multiplexer User’s ManualWarranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10 HP E1351A/53A 16-Channel FET Multiplexer Module User’s Manual
Notes100 HP E1351A/53A FET Multiplexer Error Messages Appendix C
IndexHP E1351A/53A FET Multiplexer User’s Manual*CLS, 76*ESE, 76*ESE?, 76*ESR?, 76*IDN?, 76*OPC, 76*OPC?, 76*RCL, 76*RST, 76 - 77*SAV, 76*SRE, 52, 7
connecting to direct terminals, 32 - 33connecting to tree terminals, 34list, 29, 65numbers, 11opening, 29, 64query closure, 64 - 65scanning, 65scannin
isolating, 33measurement accuracy, 33Discrete Command Parameters, 55DISPlay Subsystem, 58 - 59, 77DISPlay:MONitor:CARD, 58DISPlay:MONitor[:STATe], 59,
MMainframe Address, 14Making2-wire ohms measurements by scanning, 384-wire ohms measurements by scanning, 38continuous scans, 39, 60measurements, 34mu
voltage measurements by scanning, 36 - 37Programmingregister-based, 81 - 98Programming Language, 16QQuerychannel closure, 16, 33, 64 - 65error queue,
card numbering, 30card numbers, 18 - 19configuration, 12, 14, 51configuration with multimeter, 42, 51continuous scanning, 60logical addresses, 18 - 19
terminal module (E1353A), 43Tree Isolation Switch, 12closing FETs, 34disabling, 68enabling, 68opening, 32 - 33Tree Terminalsconnecting to switchbox ch
Chapter 1Getting Started with the HP E1351A/53AUsing This ChapterThis chapter describes the HP E1351A 16-Channel FET and theHP E1353A 16-Channel Ther
For high-speed operation (100 K switches/sec.) the scanning list isautomatically downloaded into RAM on the multiplexer module.Triggering for channel
Figure 1-1. FET Multiplexer Module Block DiagramChapter 1 Getting Started with the HP E1351A/53A 13
Switchbox and Scanning Voltmeter ConfigurationsA VXIbus instrument is a module or group of modules which perform aspecified function. For the HP E130
120 TRIGGER 70903 !Trigger the switchbox to advancethe channel list130 NEXT I !Increment count140 END Scanning Voltmeter When the multiplexer(s) is c
Programming LanguageThe examples in this manual use the Standard Commands forProgrammable Instruments (SCPI) commands, Hewlett-Packard BASIC andan HP
Chapter 2Configuring the HP E1351A/53A FETMultiplexer ModulesUsing This ChapterThis chapter shows how to configure the 16-Channel FET MultiplexerModu
Multiplexer Card NumbersHP plug-in modules installed in an HP VXIbus mainframe are treated asindependent instruments each having a unique secondary HP
The logical addresses noted in Figures 2-1, 2-2, and 2-3 apply to modulesinstalled in an HP 75000 Series B Mainframe (HP Model NumberE1300A/E1301A) or
Measuring Temperature Using Thermocouples (HP E1353A Module only) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Selecting the Interrupt Line NumberThe multiplexer module generates interrupts at the end of a downloadedscan list. The interrupt line number switch
Setting the Card ID SwitchThe multiplexer module can be an HP E1351A, HP E1352A or HP E1353Adepending on which terminal module is installed. With a n
Connecting User InputsThe 16-Channel FET consists of a component module and a terminalmodule. If the terminal module is not desired, Figure 2-7 shows
Adding Signal Conditioning Components/Current ShuntsThe multiplexer module’s terminal module allows you to add componentson each channel for the follo
Connecting Field WiringLeads for the individual channels are connected through the channelterminals on the terminal modules. Multimeters and signal g
Wiring a Terminal ModuleThe following illustrations show how to connect field wiring to the terminalmodule.Chapter 2 Configuring the HP E1351A/53A FET
Connecting Multimeters and Signal Generators Figure 2-10 shows how to connect the analog bus connector and the digitalbus handshake cable between mult
Analog Bus and Digital Bus CablesFigure 2-11 shows analog bus and digital bus cables formultiplexer-to-multiplexer and multiplexer-to-multimeter conne
Notes28 Configuring the HP E1351A/53A FET Multiplexer Modules Chapter 2
Chapter 3Using the HP E1351A/53A FET MultiplexerModulesUsing This ChapterThis chapter uses some typical examples to show how to use the16-Channel FET
:CPON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71:CTYPe? . . . .
To address specific channels within a multiplexer module in a switchbox orscanning voltmeter configuration, you must send the appropriate SCPIcommand
Multiplexer CommandsThe following commands are covered in Chapter 3. For a complete list anddescription of commands see Chapter 5, “Command Reference
Connecting Switchbox Channels to Direct TerminalsThe direct terminals provide direct access to closed channels. There is adirect terminal for each ba
Comments Isolation. The direct terminals provide a more accurate measurement thanthe tree terminals or the analog bus connector as the signal does no
Connecting Switchbox Channels to Tree Terminals forMaking MeasurementsConnect external multimeters to the A tree terminal. The SCAN:PORTABUS command
Example: ConnectChannels 02 and 10 toTree Terminals for4-Wire OhmsMeasurementThe SCAN:MODE FRES command separates Bank 0 and Bank 1 for 4-wireresistan
Scanning a Range of Switchbox ChannelsYou can scan a range of channels of a switchbox consisting of single ormultiple multiplexer modules. Scanning i
60 OUTPUT 70914;"SCAN (@100:215)"!Selects the channel list; 100selects the first channel of module#1 and 215 selects the last channelof mo
Example: Making2-Wire OhmsMeasurements byScanningUse the same setup shown in the first program example in this section,except the current source from
Example: MakingMultiple ScansThe ARM:COUNt <number> command selects multiple scanning cycles forswitchboxes with non-downloaded scans. It does
Notes4 HP E1351A/53A FET Multiplexer User’s Manual Contents
Scanning a Switchbox without a Downloaded Scan ListThis example shows a FET switchbox connected to a multimeter with theanalog bus cable. The switchb
Scanning a Switchbox with a Downloaded Scan ListThis example shows a FET switchbox connected to multimeter with theanalog bus cable and the digital bu
Scanning Voltmeter Configuration with HP E1326BThis example shows an HP E1326B Multimeter and an HP E1351A/E1353A Multiplexer combined into a single V
Measuring Temperature Using Thermocouples (HP E1353A Module only)The thermocouple terminal module automatically configures the HPE1353A FET Multiplexe
Comments Measuring Temperature with the HP El326B/El411B Multimeters. TheHP E1326B/E1411B Multimeters can directly measure channels of single ormulti
Chapter 4Understanding the HP E1351A/53A FETMultiplexer ModulesUsing This ChapterThis chapter explains techniques to scan the channels of 16-Channel
Figure 4-1. Scanning Commands46 Understanding the HP E1351A/53A FET Multiplexer Modules Chapter 4
Handshake Triggering (TRIG:SOUR BUS)Uses digital bus on faceplate of multiplexermodule. Channel Advance and ChannelClosed continuously handshake withV
Example: Scanningwith ExternalInstrumentsThis example uses the mainframe "Trig Out" port to synchronize themultiplexers to an HP 3457A Digit
Example: ScanningUsing "Trig Out" and"Event In" PortsThis example uses the mainframe "Trig Out" and "Event In"
CertificationHewlett-Packard Company certifies that this product met its published specifications at the time of shipment from the factory. Hewlett-P
Example: ScanningUsing Stand-AloneMultimeter and DigitalBus TriggeringThis example is similar to the previous one except that the multimeter’s"Ex
Example: ScanningUsing ScanningVoltmeterConfiguration andDigital Bus TriggeringIn this example the HP E1326B Multimeter is combined with a FETmultiple
Using the Scan Complete BitYou can use the Scan Complete Bit (bit 8) in the SCPI Operation StatusRegister to determine when a scanning cycle completes
Chapter 5HP E1351A/53A 16-Channel FETMultiplexer Command ReferenceUsing This ChapterThis chapter describes Standard Commands for Programmable Instrum
Command Separator A colon (:) always separates one command from the next lower levelcommand as shown below:ROUTe:SCAN:MODE VOLTColons separate the roo
Parameters Parameter Types. The following table contains explanations and examplesof parameter types you might see later in this chapter.Parameter Ty
ABORtThe ABORt subsystem stops a scan in progress when the scan is enabled viathe interface, and the trigger modes are TRIGger:SOURce BUS orTRIGger:SO
ARMThe ARM subsystem selects the number of scanning cycles (1 - 32767) foreach INIT command. This command does not apply to downloaded scanlists. Fo
DISPlayThe DISPlay subsystem monitors the channel state of a selected module (orcard). This command can only be used when the FET multiplexer modulei
:MONitor[:STATe] DISPlay:MONitor[:STATe] <mode> turns the monitor mode on or off.ParametersParameter Name Parameter Type Range of ValuesmodeBoo
Frame or chassis ground terminal—typi-cally connects to the equipment’s metalframe.Alternating current (AC).Direct current (DC). Indicates hazardous v
INITiateThe INITiate subsystem selects continuous scanning cycles and starts thescanning cycle.Subsystem Syntax INITiate:CONTinuous <mode>:CONTi
Example Enabling Continuous ScansINIT:CONT ON Enables continuous scanning.SCAN (@100:115) Sets channel list.INIT Starts scanning cycle.:CONTinuous? I
OUTPutThe OUTPut subsystem enables or disables the "Trig Out" port of the HPE1300/E1301 Mainframe.Subsystem Syntax OUTPut [:STATe] <state
[ROUTe:]The [ROUTe:] subsystem controls switching and scanning operations for themultiplexer modules in a switchbox.Subsystem Syntax [ROUTe:]CLOSe <
Example Closing Multiplexer ChannelsThis example closes channel 00 of a multiplexer module card number 1 andchannel 15 of multiplexer module card numb
Example Opening Multiplexer ChannelsThis example opens channel 00 of a multiplexer module card number 1 andchannel 15 of multiplexer module card numbe
• Scanning Operation: With a valid channel list,INITiate[:IMMediate] starts the scanning cycle and closes the firstchannel in the channel list. Succ
SCAN:MODE [ROUTe:]SCAN:MODE <mode> sets the multiplexer channels defined bythe [ROUTe:]SCAN <channel_list> command for None, Volts, 2-Wir
SCAN:PORT [ROUTe:]SCAN:PORT <port> enables/disables the tree isolation switches.SCAN:PORT ABUS closes the appropriate tree switches (for analog
SETTling[:TIME] [ROUTe:]SETTling[:TIME] <channel_list> sets the delay between receiptof a channel closing trigger, and the pulse when the FET c
Declaration of Conformityaccording to ISO/IEC Guide 22 and EN 45014Manufacturer’s Name: Hewlett-Packard CompanyLoveland Manufacturing CenterManufactur
STATusThe STATus subsystem reports the bit values of the Operation StatusRegister. This enables the Status Register to set a bit after a bit is set t
SYSTemThe SYSTem subsystem returns the error numbers and error messages inthe error queue of a switchbox, and returns the types and descriptions ofmod
:CTYPe? SYSTem:CTYPe? <number> returns the module (card) type of a selectedmodule in a switchbox.ParametersParameter Name Parameter Type Range
TRIGgerThe TRIGger subsystem commands control the scan triggering operation ofthe multiplexer modules.Subsystem Syntax TRIGger[:IMMediate]:SOURce BUS
:SOURce TRIGger:SOURce BUS | DBUS | EXTernal | HOLD | IMMediate specifiesthe trigger source to advance the channel list during scanning. ParametersPa
Example Scanning Using External TriggersIn the following example, the trigger input is applied to the HPE1300A/E1301A Mainframe’s "Event In"
IEEE 488.2 Common CommandsThe following table lists the IEEE 488.2 Common (*) Commands that the16-Channel FET Multiplexer Modules accept. The operati
Command Quick ReferenceThe following tables summarize SCPI and IEEE 488.2 Common (*)Commands for the 16-Channel FET Multiplexer Modules.SCPI Commands
Notes78 HP E1351A/53A 16-Channel FET Multiplexer Command Reference Chapter 5
Appendix AHP E1351A/53A FET MultiplexerSpecifications* Each FET is diode clamped to ±14V and a 220Ω series resistor. This limits the current to th
Notes8 HP E1351A, E1353A 16-Channel FET Multiplexer Modules User’s Manual
Notes80 HP E1351A/53A FET Multiplexer Specifications Appendix A
Appendix BHP E1351A/53A Register-BasedProgrammingAbout This AppendixThe HP E1351A and HP E1353A FET and Thermocouple FETMultiplexers are register-bas
Figure B-1. Multiplexer Registers within A16 Address SpaceFigure B-2. Registers within HP E1301/E1406 A16 Address Space82 HP E1351A/53A Register-Base
The Base Address When reading or writing to a multiplexer register, specify a hexadecimal ordecimal register address. This address consists of a base
Register Offset The register offset is the register’s location in the block of 64 address bytes.For example, with a LADDR of 112 the multiplexer’s Sca
Device Type Registerbase + 02161514131211109876543210Write UndefinedRead Model CodeStatus/Control Registerbase + 04161514131211109876543210Write Undef
Register Bit DescriptionsThis section contains a description of the function of each bit which isaddressable in each register. The bits are listed ac
Status/ControlRegisterThe Status/Control WRITE register is used to reset the module, enableinterrupts, choose direct or scan list control of the chann
Scan ControlRegisterThe Scan Control Register allows you to clear the scan list, set the triggermode and reset the pointer to the beginning of the sca
Scan ChannelConfigurationRegisterThese bits set the <channel_list> for a scan list, set the type of measurementand enable/disable the tree isola
Reader Comment SheetHP E1351A/53A 16-Channel FET Multiplexer Module User’s ManualEdition 4You can help us improve our manuals by sharing your comments
Direct ControlRegisterThe Direct Control Register allows you to set the controls for individualchannels. Note that the DIR bit in the Status/Control
INITiate[:IMMediate] is equivalent to writing a one to the TRG INT in theStatus/Control Register. The TRG INT sets itself back to zero after pulsingt
The [ROUTe:]SCAN:MODE VOLT | RES | FRES is set with C1 and C0 inthe Scan Channel or Direct Control Register. Note that to obtain theThermistor refere
Register-Based Programming for Maximum SpeedThis is an outline of the algorithm that needs to be followed to have theHP E1326B 51⁄2 Digit Multimeter d
Now write once for each channel in your scan list to the ChannelConfiguration Register. This register loads up a FIFO that will later rotateeach time
The number of readings specified in sample count will now be taken. If thesample count is more than one scan, the scan list will start over again.5.
MultimeterCommand andParameter OpcodesTable B-1 contains the multimeter command and parameter opcodes. Theopcodes used to query the parameter setting
Table B-1. Multimeter Command and Parameter Opcodes (continued)(1) Specified as a 2’s complement binary number. For three byte parameters <upper
MultimeterRegister-BasedProgramming ErrorCodesMultimeter error codes related to register-based programming are listed inTable B-2.Table B-2. Multimete
Appendix CHP E1351A/53A FET Multiplexer ErrorMessagesTable C-1 lists the error messages associated with the multiplexer modulesprogrammed with SCPI c