HP StorageWorks 20 - Modular Smart Array Specifiche Pagina 57

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 84
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 56
Replacing a SCS
II/Omodule
Before you begin
CAUTION:
Before removing a component or blank from an operational device, make sure that you have the
replacement part or blank available. Removing a component or blank impacts the airow pattern
and cooling ability of the device. Allow approximately 30 seconds before installing the new or
replacement component to ensure that conguration data about the removed component is cleared
from the system registry, but, to avoid possible overheating, insert the new or replacement component
withinoneortwominutes.Iftheinternaltemperatureexceedsacceptablelimits,thedevicemay
overheat and automatically shut down or restart.
Parts can be damaged by electrostatic discharge. Use proper anti-static protection.
Verifying component failure
Before replacing the SCSI I/O module:
Verify that the module Status LED is off or is blinking amber.
Check the array controller LCD display panel for error messages.
Removing the SCSI I/O module
CAUTION:
The SCSI I/O module is not hot-pluggable. Before replacing the module, all I/O from the servers must be
stopped and the MSA must be powered down.
1. Review all warnings, cautions, and preparation procedures as detailed in Warnings and precautions.
NOTE:
Before removing the SCSI I/O module, label all cables. This ensures their reconnection in
the correct conguration.
2. Disconnect all SCSI cables from the SCSI I/O module.
1510i Modular Smart Array maintenance and service guide