Hardware options installation 58
11. Do one of the following:
o For improved power efficiency, install an HP CS power supply in the upper bay of the RPS cage.
NOTE: To install a second redundant power supply in the redundant power supply cage, first
remove the cage EMI shield.
CAUTION: The default and redundant power supplies in the server must have the same output
power capacity. Verify that all power supplies have the same part number and label color. The
system becomes unstable and might shut down when it detects mismatched power supplies.
NOTE: To install a second redundant power supply in the redundant power supply cage, first
remove the cage EMI shield.