Figure 3-11 Wake up, success response example
Table 3-13 Device Status possible values
Code Meaning Explanation
1 OK Device is awake
0 KO Device is not awake
-1 Initializing Device is still booting
3.2.6 Cancel scan
Table 3-14 Cancel scan
?api=config&method=cancelScan
GET Description Cancels/interrupts the scanning process on the device.
Payload IN
OUT If 200, XML response with code 0
If 400, XML response with error code
Response Code 200 OK — success
400 Bad request:
Error code –10: Device is busy
401 Unauthorized access — if basic authentication fails
500 Internal Server Error — if too many request are active. Retry recommended.
Schema Request
Response
?api=common&rschema=default