Dette andre eksempelet gir skjermen beskjed om å kalibrere to forhåndsinnstillinger, den første med BT.709-
primærfarger, et D65-hvitpunkt og en BT.1886-gamma. Den andre kalibreres med DCI-P3-primærfarger, et
P3-hvitpunkt og en 2,6 gamma. Det lagrer begge kalibreringer i minneplasseringen for fabrikkinnstillinger.
<?xml version="1.0" encoding="ISO-8859-1"?>
<!--BT.709/BT.1886 calibration-->
<studiocal>
<calibration entries="2">
<calibration_info>
<preset num="3" name="BT.709" store="factory"/>
<gamma value="bt1886"/>
<target_primaries rx="0.640" ry="0.330" gx="0.300" gy="0.600"
bx="0.150" by="0.060" wx="0.3127" wy="0.329" wY="80"
external="FALSE"/>
</calibration_info>
<calibration_info>
<preset num="5" name="DCI P3" store="factory"/>
<gamma value="2.6"/>
<target_primaries rx="0.680" ry="0.320" gx="0.265" gy="0.690"
bx="0.150" by="0.060" wx="0.314" wy="0.351" wY="48"
use_uv="false" external="false"/>
</calibration_info>
</calibration>
</studiocal>
Opprettelse av ICC-prol
I noen arbeidsyter kreves en ICC-prol for den kalibrerte forhåndsinnstillingen. Denne prolen kan opprettes
ved å bruke et save_icc-merke. Dette merket gir skjermen beskjed om å beregne en ICC-prol for den
kalibrerte forhåndsinnstillingen og skrive den til USB-ashstasjonen som inneholder StudioCal XML-len.
Beregning av en ICC-prol krever at ekstra målinger gjøres etter kalibreringen, slik at kalibreringer som
utføres med et spektroradiometer kan ta betydelig lenger tid.
Dette merket inneholder ett attributt og er strukturert som følger:
<save_icc value="TRUE|FALSE"/>
Hvis "value" settes til TRUE, utføres utvidede målinger av den nedre gråtonen. Hvis den settes til FALSE,
ignoreres merket.