4. Define the following SVCPARM statement in the IEASVCxx parmlib member:
SVCPARM SVC-number,REPLACE,TYPE(3),EPNAME(JYUASVC),APF(NO),NPRMPT(NO),AR(NO)
For details, see the manual MVS Initialization and Tuning Reference.
To enable registration, you must perform an IPL again with the CLPA parameter specified.
CAUTION:
User SVCs are shared between Smart Manager for Mainframe, and Business Continuity Manager.
Therefore, you must be careful when registering a user SVC if you install Smart Manager for Mainframe
for the first time in an environment where Business Continuity Manager is installed.
Postrequisites
Setting the operating environment for Smart Manager for Mainframe (setting environment variables
or system symbols)
Related topics
Setting the operating environment for Smart Manager for Mainframe (setting environment variables
or system symbols), page 40
Notes on registering a user SVC if Business Continuity Manager is installed, page 55
Setting the operating environment for Smart Manager for
Mainframe (setting environment variables or system symbols)
This section explains how to set the operating environment for Smart Manager for Mainframe.
About the operating environment for Smart Manager for Mainframe
The operating environment settings for Smart Manager for Mainframe include the following:
The prefix of the license information dataset that registers the license key
Whether the system logger service is used to collect event logs
Whether CLI command execution logs are output to SYSLOG
Set the operating environment settings for Smart Manager for Mainframe by using either of the
following methods:
Use the environment variable (set by using the KTSETENV environment configuration command).
Use this method if you cannot perform an IPL again because the system is running. However, this
setting is invalidated if an IPL is performed again.
Use the system symbol (set for the IEASYMxx parmlib member).
To enable this setting, you must perform an IPL again. The statically-registered settings can be used
the next time an IPL is performed again.
Installation and setup40