Hp StorageWorks IP Storage Router Manuale Utente Pagina 135

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 134
Configuring SCSI Routing
135IP Storage Router SR2122-2 User Guide
To verify the configuration of a SCSI routing instance:
1. enable — Enter Administration mode.
2. Show scsirouter zeusDisplay the parameters configured for the
specified SCSI routing instance (Example 9).
Example 9: Verifying Configuration for a SCSI Routing Instance
[SR2122]# show scsirouter zeus
zeus description "(not set)"
zeus authenticate "none"
zeus primary "none"
zeus proxy server disabled
zeus failover primary "none"
zeus failover secondary "none"
zeus target naming authority "none"
zeus target log level is not available
zeus target chimaera_apps description "(not set)"
zeus target chimaera_apps Name
"iqn.1987-05.com.hp.00.d3f8a650c7deacecd97e1812d.chimaera_"
zeus target chimaera_apps enabled "TRUE"
zeus target chimaera_apps accesslist "all"
zeus target chimaera_apps lun 24 wwpn
"22:00:00:20:37:19:15:05" lun "0" I/F fci1
zeus target chimaera_eng description "(not set)"
zeus target chimaera_eng enabled "TRUE"
zeus target chimaera_eng accesslist "all"
zeus target chimaera_eng lun 17 lunwwn
"22:00:00:20:37:19:12:9d" I/F fci1
zeus target pegasus_web description "(not set)"
zeus target pegasus_web Name
"iqn.1987-05.com.hp.00.d6bf2b11ed9c88ce9299ea3f0961ad94.pega
sus_web"
zeus target pegasus_web enabled "TRUE"
zeus target pegasus_web accesslist "all"
zeus target pegasus_web lun 3 serial "LS0932210000019451JM5"
I/F fci1