Helpful hints
To replicate the configuration settings, do the following:
1. Disconnect the failed storage enclosure from the switch.
2. Connect the replacement storage enclosure to the switch. The replacement storage enclosure
must be the same model as the original one, with no existing zoning configuration information.
3. In the VSM, select the old-failed storage enclosure in the navigation tree, and then click
Replicate Zoning Configuration. The enclosure will be labelled as offline.
4. In the drop-down menu, select the replacement storage enclosure.
48 Tasks in the VSM Maintain tab