Hp 3PAR System Reporter Software Manuale Utente Pagina 184

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 183
7.16
Configuring Rules for Email Alerts
3PAR System Reporter User’s Guide System Reporter 2.8
7.4.4.5 Direction
Specifies whether the Metric should be less than (<) or greater than (>) the Limit Value for
the alert to be generated.
7.4.4.6 Limit Value
Specifies the value that the Metric is compared to. This should be a number.
write_ioszkb Write IO Size in KBytes statport, statpd,
statpd_nl7,statpd_fc10,
statpd_fc15, statpd_ssd150, statld,
statvlun
total_ioszkb Total (read + write) IO Size in
KBytes
statport, statpd,
statpd_nl7,statpd_fc10,
statpd_fc15, statpd_ssd150, statld,
statvlun
total_qlen Total queue length statport, statpd,
statpd_nl7,statpd_fc10,
statpd_fc15, statpd_ssd150, statld,
statvlun
idle_perc Percentage idle time for the
node
statcpu
total_utilperc Total utilization per second.
For instance, when the PD
utilization exceeds a given high
(say 90%) utilization meaning
that 90% of the time there is
some IO operation outstanding
at the PD.
statport, statpd,
statpd_nl7,statpd_fc10,
statpd_fc15, statpd_ssd150, statld,
statvlun
Table 7-4. Metric
Metrics Description Data Tables
Vedere la pagina 183
1 2 ... 179 180 181 182 183 184 185 186 187 188 189 ... 377 378

Commenti su questo manuale

Nessun commento