Hp 3PAR Operating System Software Manuale Utente Pagina 147

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 146
Figure 57 Communication Failure—Site 2 to Quorum Witness
Communication Failure—Site 2 to Quorum Witness and Site 1 to Site 2
In a dual-network communication failure between site 2 and the quorum witness, and between site
1 and site 2 (see Figure 58 (page 147)):
HP 3PAR StoreServ array A reacts to the isolation of HP 3PAR StoreServ array B just as it
would react to a failure of HP 3PAR StoreServ array B. However, because HP 3PAR StoreServ
array A is already source, no action is required.
A failover does not happen:
Host I/O continues to go to source volumes.
Replication of I/O across remote-copy links stops.
Figure 58 Communication Failure—Site 2 to Quorum Witness and Site 1 to Site 2
HP 3PAR Peer Persistence Quorum 147
Vedere la pagina 146
1 2 ... 142 143 144 145 146 147 148 149 150 151 152 ... 288 289

Commenti su questo manuale

Nessun commento