You begin by logging in to the SVA using a terminal window. The following command runs the
atlantis application on the FULL_DISPLAY Display Surface using the DMX-Chromium launch
script. Note the use of the application-specific command line parameter: -count 20. Launch
scripts can start from any cluster node, for example, the head or a login node.
% sva_chromium_dmx.sh -d FULL_DISPLAY \
"/usr/X11R6/lib/xscreensaver/atlantis -count 20"
For details on the syntax of the Chromium script, see the SVA Visualization System Software
Reference Guide or the sva_chromium_dmx.sh manpage.
You can also run applications interactively using this script. See Section 5.3.
6.3 Running a Workstation Application Using a Multi-Tile Display 63