HP rp7410 Guida Utente Pagina 120

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 119
HP OpenVMS I64 Support for Cell Local Memory
On servers based on the HP sx1000 chipset or HP sx2000 chipset, each cell has a cell local memory
(CLM) parameter, which determines how firmware interleaves memory residing on the cell.
NOTE: HP OpenVMS I64 does not support using CLM. Before booting OpenVMS on an
nPartition, you must ensure that the CLM parameter for each cell in the nPartition is set to zero
(0). Although you might be able to boot OpenVMS on an nPartition with CLM configured, any
memory configured as cell local is unusable, and such a configuration is untested and
unsupported.
To check CLM configuration details from an OS, use Partition Manager or the parstatus
command. For example, the parstatus -V -c# command and parstatus -V -p# command
report the CLM amount requested and CLM amount allocated for the specified cell (-c#, where
# is the cell number) or the specified nPartition (-p#, where # is the nPartition number).
To check CLM configuration details from the EFI Shell on a cell-based HP Integrity server, use
the info mem command. If the amount of "NonInterleaved Memory" reported is less than 512
MB then no CLM is configured for any cells in the nPartition (and the indicated amount of
noninterleaved memory is used by system firmware). If the info mem command reports more
than 512 MB of noninterleaved memory then use use Partition Manager or the parstatus
command to confirm the CLM configuration details.
To set the CLM configuration, use Partition Manager or the parmodify command.
Adding HP OpenVMS to the Boot Options List
On HP Integrity servers, you can use the following procedures to manage boot options list entries
for HP OpenVMS.
You can add the \efi\vms\vms_loader.efi loader to the boot options list from the EFI Shell
or EFI Boot Configuration menu (or in some versions of EFI, the Boot Option Maintenance
menu).
NOTE: OpenVMS I64 installation and upgrade procedures assist you in setting up and validating
a boot option for your system disk. HP recommends that you allow the procedure to do this.
To configure booting on Fibre Channel devices, you must use the OpenVMS I64 Boot Manager
utility (BOOT_OPTIONS.COM). For more information on this utility and other restrictions, refer
to the HP OpenVMS for Integrity Servers Upgrade and Installation Manual.
Procedure 5-15 Adding an HP OpenVMS Boot Option
This procedure adds an HP OpenVMS item to the boot options list from the EFI Shell.
To add an HP OpenVMS boot option when logged in to OpenVMS use the
@SYS$MANAGER:BOOT_OPTIONS.COM command.
1. Access the EFI Shell environment.
Log in to the management processor and enter CO to access the system console.
When accessing the console, confirm that you are at the EFI Boot Manager menu (the main
EFI menu). If at another EFI menu, select the Exit option from the sub-menus until you
return to the screen with the EFI Boot Manager heading.
From the EFI Boot Manager menu, select the EFI Shell menu option to access the EFI Shell
environment.
120 Booting and Resetting nPartitions
Vedere la pagina 119
1 2 ... 115 116 117 118 119 120 121 122 123 124 125 ... 265 266

Commenti su questo manuale

Nessun commento

CDA CI330 manuali

Manuali dei proprietari e guide per l'utente per Lavatrici CDA CI330.
We fornisce 1 manuali pdf CDA CI330 per scaricare gratuitamente in base al tipo di documento: Specifiche






Più prodotti e manuali per Lavatrici CDA

Modelli Tipo di Documento
CI230WH Specifiche   CDA CI230SI washing machine, 28 pagine
CI240WH Specifiche   CDA CI240WH washing machine, 24 pagine
CI370 Manuale delle Istruzioni   CDA CI370 washing machine, 21 pagine
CI340 Specifiche   CDA CI340 washing machine, 24 pagine
ci925 Specifiche   CDA ci925 Specifications, 36 pagine
C1370 Manuale Utente   UL TEST REPORT AND PROCEDURE [en] , 173 pagine
3Z9 Manuale Utente   3Z9 Extractors, 12 pagine
CI394 Specifiche   CDA CI394 Specifications, 36 pagine
CI340 Informazioni Techniche   CDA CI340 Technical information, 65 pagine
CI240 Specifiche   CDA CI240 Specifications, 24 pagine
ci261 Specifiche   CDA ci261 Specifications, 74 pagine