Updating SWAN Concentrator CLIP Firmware
G06.24 Software Installation and Upgrade Guide528593-005
C-17
Step 3: Initiate the Firmware Update Using TSM
8. In the $volume.subvolume box, enter the new firmware file location (the value you
entered in the SCF ALTER ADAPTER, KERNELCODE command in Step 2: Point
SWAN Concentrators to the New Firmware Object Code File). For example:
9. Click OK.
10. Click Yes when a message appears, warning that you have specified a
nonstandard firmware file location.
11. In the Firmware Update dialog box, click Perform action.
The Firmware Update Action Summary dialog box appears and displays
Completed when the SWAN CLIPs have been updated. For example:
12. When all SWAN CLIPs have been successfully updated, close the Firmware
Update Action Summary and Firmware Update dialog boxes.
VST430.vsd
VST440.vsd