Hp Integrity Essentials Pack for Linux Software Manuale Utente

Navigare online o scaricare Manuale Utente per Software Hp Integrity Essentials Pack for Linux Software. HP Integrity Essentials Pack for Linux Software User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 66
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
HP Insight Foundation Suite for Integrity with
Linux User's Guide
HP Smart Setup
HP Support Pack
HP Part Number: 5992-3193
Published: May 2011
Edition: 2.10
Vedere la pagina 0
1 2 3 4 5 6 ... 65 66

Sommario

Pagina 1 - Linux User's Guide

HP Insight Foundation Suite for Integrity withLinux User's GuideHP Smart SetupHP Support PackHP Part Number: 5992-3193Published: May 2011Edition:

Pagina 2

VariableThe name of a placeholder in a command, function, or other syntax displaythat you replace with an actual value.[ ] The contents are optional i

Pagina 3 - Table of Contents

Publication DateEditionNumberSupported VersionsSupported OSManufacturing PartNumberApril 20082.3RHEL4U4 and later, and RHEL5and RHEL5U1SLES9SP3, and S

Pagina 4 - 4 Table of Contents

— For additional information on HP products and services, see the HP website:http://www.hp.com— For the location of the nearest sales office, call:In

Pagina 5 - Table of Contents 5

1 Planning the InstallationInstalling the Linux operating system (OS) on an HP Integrity server involves preparing thehardware for the OS installation

Pagina 6 - List of Figures

The following table provides the minimum RHEL and SLES OS distributions that are supportedusing the latest HP Insight Foundation Suite for Integrity w

Pagina 7 - List of Tables

1. Go to the Open Source and Linux from HP website at:http://www.hp.com/go/integritylinux2. Click Linux certification and support matrices.3. Select t

Pagina 8

Using a Serial ConsoleA serial console is a PC running terminal emulation software, such as a Secure SHell (SSH) clientlike PuTTY (available from the

Pagina 9 - About This Document

Using the HP Smart Setup EBSU UtilityYou can use HP Smart Setup both before and after the OS is installed.HP recommends that you obtain the latest ver

Pagina 10 - Publishing History

Figure 1-3 Installation OverviewThere are minor differences in the sequence of tasks or the interface you use to perform thembased on your choice of c

Pagina 11 - Related Information

2 Preparing for InstallationPreparing your server for an OS installation involves setting up a console (VGA, serial, or both)and preparing the hardwar

Pagina 12 - HP Encourages Your Comments

© Copyright 2007–2011 Hewlett-Packard Development Company, L.P.Confidential computer software. Valid license from HP required for possession, use or c

Pagina 13 - 1 Planning the Installation

5. Verify existing device compatibility at the HP Integrity server connectivity website:http://www.hp.com/go/serverconnectivity6. Verify storage compa

Pagina 14 - Support Exceptions

3. Use the Keyboard Configuration Panel to map the Backspace character to Ctrl-H.4. Boot the server.5. Run the terminal emulator and press Enter.The M

Pagina 15

2. Make a list of all device connections so you can reconnect them after the installation iscompleted.3. Disconnect all mass storage devices from all

Pagina 16 - Using a VGA Console

5. Change directories to \EFI\boot, and then enter the following:# BootIA64.efiThe Smart Setup EBSU entry is created in the EFI Boot Manager as a sele

Pagina 17 - Installation Process

11. Change directories to \EFI\boot, and then enter the following:# BootIA64.efiThe Smart Setup EBSU entry is created in the EFI Boot Manager as a sel

Pagina 18 - 18 Planning the Installation

3 Installing the OS and Updating the ServerThis chapter provides instructions for installing Linux using the HP Smart Setup EBSU utilityor a cold inst

Pagina 19 - 2 Preparing for Installation

NOTE: The entry Smart Setup EBSU (if configured) are not displayed in all EFI BootManagers. If this entry does not appear, perform the steps detailed

Pagina 20 - Setting Up a Console

Based on the type of server, the option to configure either the Advanced Configuration andPower Interface (ACPI) or maximum payload size (MPS) setting

Pagina 21 - Preparing the Server Hardware

NOTE: This setting cannot be changed for the rx2660, rx3600, and rx6600 PCI-X servers,therefore, this menu option is not available.5. Select Configure

Pagina 22 - Enabling a CD/DVD Device

NOTE: If you have just configured a RAID volume, then you must reboot the system sothat it is detected. Additionally, on rx7620 and rx8620 servers, yo

Pagina 23 - Enabling a USB Device

Table of ContentsAbout This Document...9Addition

Pagina 24 - 24 Preparing for Installation

Figure 3-10 Page 1: Update Firmware, Cell-Based ServersFor either server type, all hardware devices present are listed and automatically selected ifup

Pagina 25

13. Make the appropriate selections for the options on Smart Setup Page 2 as follows:a. For question 2, specify the logical volume on which you want t

Pagina 26

18. A prompt is displayed with a message directing you to insert the Linux installer media inthe CD or DVD drive, as shown in Figure 3-13.IMPORTANT: I

Pagina 27

To install the OS, follow these steps:1. Begin the OS installation as described in the installation guide for the OS you are installing.2. Select the

Pagina 28

Installing the Fibre Channel HBA Drivers or Inbox Driver Kits for LinuxIf your system contains Fibre Channel Host Bus Adapters (HBAs), you should ensu

Pagina 29

1. Go to http://www.hp.com/.2. Click Support & Drivers.3. Click Download drivers and software (and firmware).4. In the For Product field, enter th

Pagina 30

NOTE: To avoid any potential issues, review the known issue “Installing the MPT Fusion HBADriver on RHEL 5 and RHEL 5+ using a Xen Kernel Hangs the Se

Pagina 31

4 EFI and HP Smart Setup Media UtilitiesThis chapter describes functions available through the HP Smart Setup EBSU utility and providesan easy-to-use

Pagina 32

Figure 4-1 EFI Boot ManagerEFI ShellAvailable as a selection from the EFI Boot Manager, the EFI Shell provides a command-lineinterface from which you

Pagina 33 - Updating the Server

The HP Smart Setup EBSU utility provides the following capabilities:• Configure Storage Adapters—Configures bootable I/O adapters. A submenu provides

Pagina 34

EFI Boot Manager...37EFI Shel

Pagina 36

5 Installing and Using the HP Support PackThis chapter provides instructions for installing and using the HP Support Pack. This contentsof this softwa

Pagina 37 - Using EFI

For more information, see HP Insight Management Agents for Linux on HP Integrity Servers:Installation Guide and Release Notes:http://www.docs.hp.com/e

Pagina 38 - HP Smart Setup Utilities

HP Array Configuration Utility – Command Line InterfaceHP Array Configuration Utility – Command Line Interface (ACU-CLI) for Linux on Itanium-basedsys

Pagina 39 - HP Smart Setup Utilities 39

The WBEM schema files for the HP Utilization Provider are installed at /opt/util/mof. Formore information, see utild(1M).HP SmartSetup Scripting Toolk

Pagina 40

should verify that you do not need these utilities before you remove them. The HPIMA, ACU-CLI,and HP SMH utilities do not require OpenPegasus.The inst

Pagina 41 - HP Insight Management Agents

3. Set execute permissions on the downloaded file:# chmod a+x jrockit-R27.5.0-jdk1.5.0_14-linux-ipf.bin4. Run the self-extracting binary to extract th

Pagina 42 - HP nPartition Commands

1. Start the installer:# ./install.shThe following message is displayed:Welcome to the HP Insight Foundation suite for Integrity with Linux version *.

Pagina 43 - Small Footprint CIM Broker

10. Install nPartition Commands11. Install The nPartition Management GUI for HP Integrity servers.12. Install HP WBEM Providers for Linux13. Install E

Pagina 44 - Removing OpenWBEM

SNMP-based providers are chosen for installation,then HP SMX is removed first to avoid conflicts.Update all products To update all the software produc

Pagina 45

Partitioning Fibre Channel HBA Adapters...58Installing the MPT

Pagina 46 - Running the Installer

NOTE: If you need to use a proxy to access the repository, consult the manual pages of the toolyou are using to access the repository. for example, us

Pagina 47

A Configuring and Using a Serial ConsoleBefore the Linux operating system (OS) is booted, all console interaction occurs through EFI. Tomodify the def

Pagina 48

IMPORTANT: Exactly one UART must be selected in the EFI Console-In/Out tables for a serialconsole to work. The UART selected in this table is ttyS0.Th

Pagina 49

B HP Support Pack DependenciesSome software products contained in the HP Support Pack have dependencies or prerequisitesthat may or may not, already b

Pagina 50

glibc opensslopen64-4.2.3-xxx.ia64.rpm need below packages: gcc glibc info perlRHEL5The following list provides information about software contained

Pagina 51 - Configuring a Serial Console

glibc libstdc++ libunwindhp.com-npartition-cmds-1.03.00-xxx.sles10.ia64.rpm need below packages: glibc libgcc libstdc++ libunwindhp.com-parmgr-2.02.0

Pagina 53 - RHEL4 53

C Known IssuesThis appendix contains known issues with the HP Insight Foundation Suite for Integrity withLinux product, which undergoes rigorous testi

Pagina 54

1. Shutdown SFCB by running the following as root user:# /etc/init.d/sfcb stop2. Edit the /etc/pam.d.sfcb config file by making the following edit:Re

Pagina 55 - SLES11 55

This is the result of the MPT Fusion driver rebuilding the initrd file and modifying elilo.confwhen the it is installed. The following is a comparison

Pagina 56

List of Figures1-1 Serial Console Configuration...

Pagina 57 - C Known Issues

label=HP #Corresponds to kernel 2.6.18-92.el5xen initrd=HP-initrd-2.6.18-92.el5xen.img read-only root=/dev/Vo

Pagina 58 - Kernel Hangs the Server

D Supported Products MatrixThis appendix lists the adapters that are supported by the HP Insight Foundation Suite forIntegrity with Linux in each of t

Pagina 59

Table D-1 Supported Products Matrix (continued)SLES SupportRHEL SupportDescriptionPartNumber1110 SP210 SP1105U154U64U44U34U14LANXXXX4-port GbE Mezz447

Pagina 60 - 60 Known Issues

Table D-1 Supported Products Matrix (continued)SLES SupportRHEL SupportDescriptionPartNumber1110 SP210 SP1105U154U64U44U34U14XXXXEmbedded I/O forBL860

Pagina 61 - D Supported Products Matrix

Table D-1 Supported Products Matrix (continued)SLES SupportRHEL SupportDescriptionPartNumber1110 SP210 SP1105U154U64U44U34U14XXXXHP PCIe SmartArray E5

Pagina 62

Table D-1 Supported Products Matrix (continued)SLES SupportRHEL SupportDescriptionPartNumber1110 SP210 SP1105U154U64U44U34U14XXXXHP PCI-X 2p1000BT, 2p

Pagina 63

Table D-1 Supported Products Matrix (continued)SLES SupportRHEL SupportDescriptionPartNumber1110 SP210 SP1105U154U64U44U34U14XXXXEmbedded I/O forBL860

Pagina 64

List of Tables1-1 Supported Minimum OS Distributions by HP Integrity Server...142-1 Graphics Support o

Pagina 66

About This DocumentThis document describes how to use the HP Insight Foundation Suite for Integrity with Linux(IFIL) V2.10 product.• The HP Smart Setu

Commenti su questo manuale

Nessun commento