Figure 24 Disabling trap severities
e. Trap categories must equal Other for either VC-Enet traps or VC-FC traps. Do not
select both. From the Add a SNMP Trap Destination page, click Advanced, click
More, and then select either of the following:
On the VC-Enet Traps box, select Other, as shown in the following figure.
On the VC-FC Traps box, select Other.
Figure 25 Selecting trap categories
f. To disable Virtual Connect Manager traps, from the Add a SNMP Trap Destination
page, click Advanced, and then click More. The right side must be empty, as shown
in the following figure.
Figure 26 Disabling Virtual Connect Manager traps
40 Managing VC Domains