EV Timeout Error - The recovery server option environment variable, that contains the
status, cannot be accessed. The attempted access timed out.
Unknown - The Storage Agents cannot determine the recovery server option status for this
storage system.
Preferred Path Mode displays the storage system active/active preferred path mode. The
following values are possible:
Not Active/Active - The storage system is not configured as active/active.
Automatic - The storage system automatically selects the preferred path for each logical
drive based on host I/O patterns.
Manual - The preferred path for each logical drive is manually configured by the storage
system administrator.
Unknown - The Storage Agents cannot determine the preferred path mode of the storage
system.
Internal or External Storage System Information
This information is not available for all types of storage systems. Internal storage system information
will be displayed with the External Array Storage System Information. External storage systems
will be listed in the Mass Storage submenu under Storage Boxes. Select the storage system in the
submenu to display the external storage system information. The following information will be
displayed for the storage system backplane:
Vendor displays the name of the vendor of storage system backplane. It can be used for
identification purposes.
Model displays the model name of the storage system backplane. It can be used for
identification purposes.
Firmware Revision displays the firmware revision level of storage system backplane.
Board Revision displays the board revision level of storage system backplane.
Serial Number displays the serial number of the storage system backplane. All backplanes
do not have a serial number. In this case N/A will be displayed.
Version displays the version of storage system backplane.
Fan Status displays the current status of the fans in the storage system backplane. The following
values are possible:
OK - The fans are installed and operating normally.
Degraded - At least one fan has failed, but there is still sufficient cooling capacity to allow
the storage system to continue. The failed fan should be replaced.
Degraded (Fan 1 Failed) - The fan in bay 1 has failed, but there is still sufficient cooling
capacity to allow the storage system to continue. The failed fan should be replaced.
Degraded (Fan 2 Failed) - The fan in bay 2 has failed, but there is still sufficient cooling
capacity to allow the storage system to continue. The failed fan should be replaced.
Failed - One or more fans have failed and there is insufficient cooling capacity to protect
the storage system from damage. The failed fans should be replaced.
Not Installed - This storage system backplane does not have a fan installed.
70 Agent information
Vedere la pagina 69
1 2 ... 65 66 67 68 69 70 71 72 73 74 75 ... 176 177

Commenti su questo manuale

Nessun commento

CDA CI330 manuali

Manuali dei proprietari e guide per l'utente per Lavatrici CDA CI330.
We fornisce 1 manuali pdf CDA CI330 per scaricare gratuitamente in base al tipo di documento: Specifiche






Più prodotti e manuali per Lavatrici CDA

Modelli Tipo di Documento
CI230WH Specifiche   CDA CI230SI washing machine, 28 pagine
CI240WH Specifiche   CDA CI240WH washing machine, 24 pagine
CI370 Manuale delle Istruzioni   CDA CI370 washing machine, 21 pagine
CI340 Specifiche   CDA CI340 washing machine, 24 pagine
ci925 Specifiche   CDA ci925 Specifications, 36 pagine
C1370 Manuale Utente   UL TEST REPORT AND PROCEDURE [en] , 173 pagine
3Z9 Manuale Utente   3Z9 Extractors, 12 pagine
CI394 Specifiche   CDA CI394 Specifications, 36 pagine
CI340 Informazioni Techniche   CDA CI340 Technical information, 65 pagine
CI240 Specifiche   CDA CI240 Specifications, 24 pagine
ci261 Specifiche   CDA ci261 Specifications, 74 pagine